Specifications

Comfort Reference Value – 5th Generation of STÖBER Inverters
STÖBER
ANTRIEBSTECHNIK
11. Used Parameters
KSW-97
A.. Inverter
Par. Description Fieldbus-
address
A234.3
Global
r=2, w=2
2. trans. PDO Mapping Tx. 4. mapped Parameter: For 2nd PDO channel. See A233.3.
NOTE
The parameter is only visible when a CAN device controller is selected in the device configuration
or the appropriate blocks were used with the option for free, graphic programming.
Fieldbus: 1LSB=1; Type: U32; raw value:USS-Adr; USS-Adr: 01 3A 80 03 hex
1 Only visible when the CAN 5000 option is installed or when CAN 5000 was selected as option
module 2 in the device configuration.
20EAh 3h
A234.4
Global
r=2, w=2
2. trans. PDO Mapping Tx. 5. mapped Parameter: For 2nd PDO channel. See A233.4.
NOTE
The parameter is only visible when a CAN device controller is selected in the device configuration
or the appropriate blocks were used with the option for free, graphic programming.
Fieldbus: 1LSB=1; Type: U32; raw value:USS-Adr; USS-Adr: 01 3A 80 04 hex
1 Only visible when the CAN 5000 option is installed or when CAN 5000 was selected as option
module 2 in the device configuration.
20EAh 4h
A234.5
Global
r=2, w=2
2. trans. PDO Mapping Tx. 6. mapped Parameter: For 2nd PDO channel. See A233.5.
NOTE
The parameter is only visible when a CAN device controller is selected in the device configuration
or the appropriate blocks were used with the option for free, graphic programming.
Fieldbus: 1LSB=1; Type: U32; raw value:USS-Adr; USS-Adr: 01 3A 80 05 hex
1 Only visible when the CAN 5000 option is installed or when CAN 5000 was selected as option
module 2 in the device configuration.
20EAh 5h
A237
Global
read (1)
1. rec. PDO-Mapped Len: Indication parameter indicating in bytes the size of the expected
receive telegram of the 1st PDO channel for the current parameterization.
NOTE
The parameter is only visible when a CAN device controller is selected in the device configuration
or the appropriate blocks were used with the option for free, graphic programming.
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 01 3B 40 00 hex
1 Only visible when the CAN 5000 option is installed or when CAN 5000 was selected as option
module 2 in the device configuration.
20EDh 0h
A238
Global
read (2)
2. rec. PDO-Mapped Len: For 2nd PDO channel. See A237.
NOTE
The parameter is only visible when a CAN device controller is selected in the device configuration
or the appropriate blocks were used with the option for free, graphic programming.
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 01 3B 80 00 hex
1 Only visible when the CAN 5000 option is installed or when CAN 5000 was selected as option
module 2 in the device configuration.
20EEh 0h
A241
Global
read (1)
1. trans. PDO-Mapped Len: Indication parameter indicating in bytes the size of the expected
send telegram of the 1st PDO channel for the current parameterization.
NOTE
The parameter is only visible when a CAN device controller is selected in the device configuration
or the appropriate blocks were used with the option for free, graphic programming.
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 01 3C 40 00 hex
1 Only visible when the CAN 5000 option is installed or when CAN 5000 was selected as option
module 2 in the device configuration.
20F1h 0h