Specifications

Comfort Reference Value – 5th Generation of STÖBER Inverters
STÖBER
ANTRIEBSTECHNIK
11. Used Parameters
KSW-95
A.. Inverter
Par. Description Fieldbus-
address
A230.2
Global
r=2, w=2
2. trans. PDO Parameter . Inhibit Time: Pause time for PDO channel 2. See A229.2.
NOTE
The parameter is only visible when a CAN device controller is selected in the device configuration
or the appropriate blocks were used with the option for free, graphic programming.
Value range in 100 us: 0 ... 0 ... 65535
Fieldbus: 1LSB=1·100 us; Type: U16; USS-Adr: 01 39 80 02 hex
1 Only visible when the CAN 5000 option is installed or when CAN 5000 was selected as option
module 2 in the device configuration.
20E6h 2h
A230.3
Global
r=2, w=2
2. trans. PDO Parameter . Event Timer: For PDO channel 2. See A229.3.
NOTE
The parameter is only visible when a CAN device controller is selected in the device configuration
or the appropriate blocks were used with the option for free, graphic programming.
Value range in ms: 0 ... 0 ... 65535
Fieldbus: 1LSB=1ms; Type: U16; USS-Adr: 01 39 80 03 hex
1 Only visible when the CAN 5000 option is installed or when CAN 5000 was selected as option
module 2 in the device configuration.
20E6h 3h
A233.0
Global
r=1, w=1
1. trans. PDO Mapping Tx. 1. mapped Parameter: Address of the parameter which is
imaged first on the 1st PDO channel for sending.
NOTE
The parameter is only visible when a CAN device controller is selected in the device configuration
or the appropriate blocks were used with the option for free, graphic programming.
Value range: A00 ... E200 ... A.Gxxx.yyyy (Parameter number in plain text)
Fieldbus: 1LSB=1; Type: U32; raw value:USS-Adr; USS-Adr: 01 3A 40 00 hex
1 Only visible when the CAN 5000 option is installed or when CAN 5000 was selected as option
module 2 in the device configuration.
20E9h 0h
A233.1
Global
r=1, w=1
1. trans. PDO Mapping Tx. 2. mapped Parameter: Address of the parameter which is
imaged second on the 1st PDO channel for sending.
NOTE
The parameter is only visible when a CAN device controller is selected in the device configuration
or the appropriate blocks were used with the option for free, graphic programming.
Value range: A00 ... A101 ... A.Gxxx.yyyy (Parameter number in plain text)
Fieldbus: 1LSB=1; Type: U32; raw value:USS-Adr; USS-Adr: 01 3A 40 01 hex
1 Only visible when the CAN 5000 option is installed or when CAN 5000 was selected as option
module 2 in the device configuration.
20E9h 1h
A233.2
Global
r=1, w=1
1. trans. PDO Mapping Tx. 3. mapped Parameter: Address of the parameter which is
imaged third on the 1st PDO channel for sending.
NOTE
The parameter is only visible when a CAN device controller is selected in the device configuration
or the appropriate blocks were used with the option for free, graphic programming.
Value range: A00 ... D200 ... A.Gxxx.yyyy (Parameter number in plain text)
Fieldbus: 1LSB=1; Type: U32; raw value:USS-Adr; USS-Adr: 01 3A 40 02 hex
1 Only visible when the CAN 5000 option is installed or when CAN 5000 was selected as option
module 2 in the device configuration.
20E9h 2h