Specifications

Comfort Reference Value – 5th Generation of STÖBER Inverters
STÖBER
ANTRIEBSTECHNIK
11. Used Parameters
KSW-93
A.. Inverter
Par. Description Fieldbus-
address
A226.1
Global
r=2, w=2
2. rec. PDO Mapping Rx. 2. mapped Parameter: For 2nd PDO channel, see A225.1.
NOTE
The parameter is only visible when a CAN device controller is selected in the device configuration
or the appropriate blocks were used with the option for free, graphic programming.
Fieldbus: 1LSB=1; Type: U32; raw value:USS-Adr; USS-Adr: 01 38 80 01 hex
1 Only visible when the CAN 5000 option is installed or when CAN 5000 was selected as option
module 2 in the device configuration.
20E2h 1h
A226.2
Global
r=2, w=2
2. rec. PDO Mapping Rx. 3. mapped Parameter: For 2nd PDO channel, see A225.2.
NOTE
The parameter is only visible when a CAN device controller is selected in the device configuration
or the appropriate blocks were used with the option for free, graphic programming.
Fieldbus: 1LSB=1; Type: U32; raw value:USS-Adr; USS-Adr: 01 38 80 02 hex
1 Only visible when the CAN 5000 option is installed or when CAN 5000 was selected as option
module 2 in the device configuration.
20E2h 2h
A226.3
Global
r=2, w=2
2. rec. PDO Mapping Rx. 4. mapped Parameter: For 2nd PDO channel, see A225.3.
NOTE
The parameter is only visible when a CAN device controller is selected in the device configuration
or the appropriate blocks were used with the option for free, graphic programming.
Fieldbus: 1LSB=1; Type: U32; raw value:USS-Adr; USS-Adr: 01 38 80 03 hex
1 Only visible when the CAN 5000 option is installed or when CAN 5000 was selected as option
module 2 in the device configuration.
20E2h 3h
A226.4
Global
r=2, w=2
2. rec. PDO Mapping Rx. 5. mapped Parameter: For 2nd PDO channel, see A225.4.
NOTE
The parameter is only visible when a CAN device controller is selected in the device configuration
or the appropriate blocks were used with the option for free, graphic programming.
Fieldbus: 1LSB=1; Type: U32; raw value:USS-Adr; USS-Adr: 01 38 80 04 hex
1 Only visible when the CAN 5000 option is installed or when CAN 5000 was selected as option
module 2 in the device configuration.
20E2h 4h
A226.5
Global
r=2, w=2
2. rec. PDO Mapping Rx. 6. mapped Parameter: For 2nd PDO channel, see A225.5.
NOTE
The parameter is only visible when a CAN device controller is selected in the device configuration
or the appropriate blocks were used with the option for free, graphic programming.
Fieldbus: 1LSB=1; Type: U32; raw value:USS-Adr; USS-Adr: 01 38 80 05 hex
1 Only visible when the CAN 5000 option is installed or when CAN 5000 was selected as option
module 2 in the device configuration.
20E2h 5h
A229.0
Global
r=2, w=2
1. trans. PDO Parameter . COB-ID: Specifies the identifier for which the inverter sends the
telegrams for the 1st PDO channel to the master. Usually the default value should not be changed
since the automatic identifier assignment after the Pre-Defined Connection Set is also disabled. If
the value is 0 or bit 31 is 1, this service is off.
NOTE
The parameter is only visible when a CAN device controller is selected in the device configuration
or the appropriate blocks were used with the option for free, graphic programming.
Value range: 0 ... 384 ... 4294967295
Fieldbus: 1LSB=1; Type: U32; USS-Adr: 01 39 40 00 hex
1 Only visible when the CAN 5000 option is installed or when CAN 5000 was selected as option
module 2 in the device configuration.
20E5h 0h