Specifications

Comfort Reference Value – 5th Generation of STÖBER Inverters
STÖBER
ANTRIEBSTECHNIK
11. Used Parameters
KSW-86
A.. Inverter
Par. Description Fieldbus-
address
A141
Global
read (0)
LCD line1: Indication as character string of the bottom display line.
Fieldbus: Type: Str16; USS-Adr: 01 23 40 00 hex
208Dh 0h
A142
Global
read (3)
Key code: Code of the effective key.. 0=none, 1=LEFT, 2=RIGHT, 3=AB, 4=AUF, 5=#, 6=ESC,
7=F1, 8=F2, 9=F3, 10=F4, 11=HAND, 12= EIN, 13=AUS, 14=I/O
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 01 23 80 00 hex
208Eh 0h
A144
Global
r=3, w=0
Remote key code: Key activations can be simulated by writing this parameter. For meaning,
see A142.
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 01 24 00 00 hex
2090h 0h
A146
Axis
r=3, w=3
Display Mode: Mit den Parametern A146 bis A149 wird die Display-Anzeige des Umrichters
parametriert. In A146 wird der Display-Modus eingestellt. Bei der Einstellung 0: Anzeige
Geschw./Strom wird die Standardanzeige verwendet. Ist A146 auf 2:Terminal eingestellt, werden
die in A147 und A148 eingetragenen Zeichenketten angezeigt. Damit kann zum Beispiel eine
Meldung der SPS dargestellt werden. Bei der Auswahl 4:Parameter aus A149 + BEH wird der Wert
des in A149 eingetragenen Parameters angezeigt.
0: display speed/current;
2: terminal;
4: Parameter from A149+MU;
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 01 24 80 00 hex
2092h 0h
A147
Axis
r=3, w=3
Line 0: The indication on the display of the inverter is parameterized with parameters A146 to
A149. When A146 is set to 2:terminal, the character strings entered in A147 and A148 are
indicated. For example, this can be used to display a message from the PLC.
Fieldbus: Type: Str16; USS-Adr: 01 24 C0 00 hex
2093h 0h
A148
Axis
r=3, w=3
Line 1: The indication on the display of the inverter is parameterized with parameters A146 to
A149. When A146 is set to 2:terminal, the character strings entered in A147 and A148 are
indicated. For example, this can be used to display a message from the PLC.
Fieldbus: Type: Str16; USS-Adr: 01 25 00 00 hex
2094h 0h
A149
Axis
r=3, w=3
Display parameter: The indication on the display of the inverter is parameterized with
parameters A146 to A149. When A146 is set to 4:Parameter from A149 + MU, the value of the
parameter entered in A149 is indicated.
Value range: A00 ... 1.D399 ... A.Gxxx.yyyy (Parameter number in plain text)
Fieldbus: 1LSB=1; Type: U32; raw value:USS-Adr; USS-Adr: 01 25 40 00 hex
2095h 0h
A150
Axis, OFF
r=1, w=3
Cycle time: Cycle time of the real-time configuration on the axis. The load of the real-time task
can be checked in parameter E191 runtime usage. When the computing load becomes too great,
the event "57:runtime usage" is triggered.
NOTE
Changing this parameter may mean that a changed configuration is detected when you go online
with POSITool.
4: 1ms;
5: 2ms;
6: 4ms;
7: 8ms;
8: 16ms;
9: 32ms;
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 01 25 80 00 hex
2096h 0h