Specifications

Comfort Reference Value – 5th Generation of STÖBER Inverters
STÖBER
ANTRIEBSTECHNIK
11. Used Parameters
KSW-85
A.. Inverter
Par. Description Fieldbus-
address
A114.2
Global
r=1, w=1
USS PZD Mapping Tx 3. mapped Parameter: Address of the parameter which is imaged
third in the contents of the process data telegram (sending direction as seen by the inverter).
NOTE
The parameter is only visible when a USS device controller is selected in the device configuration
or the appropriate blocks were used with the option for free, graphic programming.
Fieldbus: 1LSB=1; Type: U32; raw value:USS-Adr; USS-Adr: 01 1C 80 02 hex
2072h 2h
A114.3
Global
r=1, w=1
USS PZD Mapping Tx 4. mapped Parameter: Address of the parameter which is imaged
fourth in the contents of the process data telegram (sending direction as seen by the inverter).
NOTE
The parameter is only visible when a USS device controller is selected in the device configuration
or the appropriate blocks were used with the option for free, graphic programming.
Fieldbus: 1LSB=1; Type: U32; raw value:USS-Adr; USS-Adr: 01 1C 80 03 hex
2072h 3h
A114.4
Global
r=1, w=1
USS PZD Mapping Tx 5. mapped Parameter: Address of the parameter which is imaged
fifth in the contents of the process data telegram (sending direction as seen by the inverter).
NOTE
The parameter is only visible when a USS device controller is selected in the device configuration
or the appropriate blocks were used with the option for free, graphic programming.
Fieldbus: 1LSB=1; Type: U32; raw value:USS-Adr; USS-Adr: 01 1C 80 04 hex
2072h 4h
A114.5
Global
r=1, w=1
USS PZD Mapping Tx 6. mapped Parameter: Address of the parameter which is imaged
sixth in the contents of the process data telegram (sending direction as seen by the inverter).
NOTE
The parameter is only visible when a USS device controller is selected in the device configuration
or the appropriate blocks were used with the option for free, graphic programming.
Fieldbus: 1LSB=1; Type: U32; raw value:USS-Adr; USS-Adr: 01 1C 80 05 hex
2072h 5h
A117
Global
read (1)
USS PZD Tx Len: Indicator parameter which indicates the length in bytes of the process data
telegram to be sent with actual values to the USS master for the current parameterization.
NOTE
The parameter is only visible when a USS device controller is selected in the device configuration
or the appropriate blocks were used with the option for free, graphic programming.
Value range: 0 ... 0 ... 255
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 01 1D 40 00 hex
2075h 0h
A118
Global
r=1, w=1
USS PZD scaling: The selection is made here between internal raw values and whole numbers
for the representation/scaling of parameter values during transmission via the process data
telegram. Regardless of this setting, the representation can be selected separately via the read-
parameter or write-parameter services.
NOTE
The parameter is only visible when a USS device controller is selected in the device configuration
or the appropriate blocks were used with the option for free, graphic programming.
0: integer without point; Values are transferred as whole number in user units * number of positions
after the decimal point to the 10th power.
1: native
; Values are transferred in the internal inverter raw format (e.g., increments).
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 01 1D 80 00 hex
2076h 0h
A140
Global
read (0)
LCD line0: Indication as character string of the top display line.
Fieldbus: Type: Str16; USS-Adr: 01 23 00 00 hex
208Ch 0h