Specifications

Comfort Reference Value – 5th Generation of STÖBER Inverters
STÖBER
ANTRIEBSTECHNIK
11. Used Parameters
KSW-82
A.. Inverter
Par. Description Fieldbus-
address
A94.5
Global
r=1, w=1
PZD ActValue Mapping Tx 6. mapped Parameter: Address of the parameter which is
imaged sixth in the contents of the process data channel (sending direction as seen by the
inverter).
Fieldbus: 1LSB=1; Type: U32; raw value:USS-Adr; USS-Adr: 01 17 80 05 hex
205Eh 5h
A95.0
Global
r=3, w=3
PZD ActValue Mapping 2Tx 1. mapped Parameter: When more parameters are to be
imaged than can be specified in A94, this parameter offers a possible extension. See A94.0.
Fieldbus: 1LSB=1; Type: U32; raw value:USS-Adr; USS-Adr: 01 17 C0 00 hex
205Fh 0h
A95.1
Global
r=3, w=3
PZD ActValue Mapping 2Tx 2. mapped Parameter: For extension of A94, see A94.1.
Fieldbus: 1LSB=1; Type: U32; raw value:USS-Adr; USS-Adr: 01 17 C0 01 hex
205Fh 1h
A95.2
Global
r=3, w=3
PZD ActValue Mapping 2Tx 3. mapped Parameter: For extension of A94, see A94.2.
Fieldbus: 1LSB=1; Type: U32; raw value:USS-Adr; USS-Adr: 01 17 C0 02 hex
205Fh 2h
A95.3
Global
r=3, w=3
PZD ActValue Mapping 2Tx 4. mapped Parameter: For extension of A94, see A94.3.
Fieldbus: 1LSB=1; Type: U32; raw value:USS-Adr; USS-Adr: 01 17 C0 03 hex
205Fh 3h
A95.4
Global
r=3, w=3
PZD ActValue Mapping 2Tx 5. mapped Parameter: For extension of A94, see A94.4.
Fieldbus: 1LSB=1; Type: U32; raw value:USS-Adr; USS-Adr: 01 17 C0 04 hex
205Fh 4h
A95.5
Global
r=3, w=3
PZD ActValue Mapping 2Tx 6. mapped Parameter: For extension of A94, see A94.5.
Fieldbus: 1LSB=1; Type: U32; raw value:USS-Adr; USS-Adr: 01 17 C0 05 hex
205Fh 5h
A97
Global
read (1)
PZD ActValue Len: Indicator parameter which indicates the length in bytes of the current
process data with actual values (data from inverter to PROFIBUS master) for the current
parameterization.
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 01 18 40 00 hex
1 Only visible when a PROFIBUS device controller is selected in the device configuration or the
appropriate blocks were used with the option for free, graphic programming.
2061h 0h
A100
Global
r=3, w=3
Fieldbusscaling: The selection is made here between internal raw values and whole numbers
for the representation/scaling of process data values during transmission via PZD channel.
Regardless of this setting, the representation is always the whole number via PKW channel and the
non cyclic parameter channel.
CAUTION
When "0:integer" is parameterized (scaled values), the runtime load increases significantly and it
may become necessary to increase A150 Cycle time to avoid the fault "57:runtime usage" or
"35:Watchdog."
With few exceptions, the PKW channel is always transferred in scaled format.
0: integer without point; Values are transferred as whole number in user units * 10 to the power of
the number of positions after the decimal point.
1: native
; Values are transferred at optimized speed in the internal inverter raw format (e.g.,
increments).
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 01 19 00 00 hex
1 Only visible when a PROFIBUS device controller is selected in the device configuration or the
appropriate blocks were used with the option for free, graphic programming.
2064h 0h