Specifications

Comfort Reference Value – 5th Generation of STÖBER Inverters
STÖBER
ANTRIEBSTECHNIK
11. Used Parameters
KSW-80
A.. Inverter
Par. Description Fieldbus-
address
A85
Global
read (3)
PROFIBUS diagnostic: Indication of internal inverter diagnostic information on the PROFIBUS
DP interface. See separate supplementary documentation (publ. no. 441687).
Fieldbus: 1LSB=1; Type: U16; USS-Adr: 01 15 40 00 hex
1 Only visible when a PROFIBUS device controller is selected in the device configuration or the
appropriate blocks were used with the option for free, graphic programming.
2055h 0h
A86
Global
read (1)
PROFIBUS configuration: The inverter offers various ways (PPO types) to transfer cyclic user
data via PROFIBUS DP. These can be configured in the GSD file STOE5005.gsd on the controller
(bus master). This indication parameter can be used to check which of the possible configurations
was chosen.
0: No data communication via PROFIBUS started
1: PPO1: 4 PKW, 2 PZD
2: PPO2: 4 PKW, 6 PZD
3: PPO3: 0 PKW, 2 PZD
4: PPO4: 0 PKW, 6 PZD
5: PPO5: 4 PKW, 10 PZD
6: PPO2: 4 PKW, 6 PZD consis. 2 W
7: PPO4: 0 PKW, 6 PZD consis. 2 W
8: PPO5: 4 PKW, 10 PZD consis. 2 W
Fieldbus: 1LSB=1; Type: U16; USS-Adr: 01 15 80 00 hex
1 Only visible when a PROFIBUS device controller is selected in the device configuration or the
appropriate blocks were used with the option for free, graphic programming.
2056h 0h
A87
Global
r=3, w=3
Activate serial baudrate: Starting with V 5.1, writing in A81 no longer changes the baud rate
immediately. The change now takes place only after device OFF/ON or A87=1 (activate baud rate).
This makes the reaction the same as the reaction of the fieldbuses.
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 01 15 C0 00 hex
2057h 0h
A90.0
Global
r=1, w=1
PZD Setpoint Mapping Rx 1. mapped Parameter: Address of the parameter which is
imaged first from the contents of the process data channel (receiving direction as seen by the
inverter).
Fieldbus: 1LSB=1; Type: U32; raw value:USS-Adr; USS-Adr: 01 16 80 00 hex
205Ah 0h
A90.1
Global
r=1, w=1
PZD Setpoint Mapping Rx 2. mapped Parameter: Address of the parameter which is
imaged second from the contents of the process data channel (receiving direction as seen by the
inverter).
Fieldbus: 1LSB=1; Type: U32; raw value:USS-Adr; USS-Adr: 01 16 80 01 hex
205Ah 1h
A90.2
Global
r=1, w=1
PZD Setpoint Mapping Rx 3. mapped Parameter: Address of the parameter which is
imaged third from the contents of the process data channel (receiving direction as seen by the
inverter).
Fieldbus: 1LSB=1; Type: U32; raw value:USS-Adr; USS-Adr: 01 16 80 02 hex
205Ah 2h
A90.3
Global
r=1, w=1
PZD Setpoint Mapping Rx 4. mapped Parameter: Address of the parameter which is
imaged fourth from the contents of the process data channel (receiving direction as seen by the
inverter).
Fieldbus: 1LSB=1; Type: U32; raw value:USS-Adr; USS-Adr: 01 16 80 03 hex
205Ah 3h
A90.4
Global
r=1, w=1
PZD Setpoint Mapping Rx 5. mapped Parameter: Address of the parameter which is
imaged fifth from the contents of the process data channel (receiving direction as seen by the
inverter).
Fieldbus: 1LSB=1; Type: U32; raw value:USS-Adr; USS-Adr: 01 16 80 04 hex
205Ah 4h
A90.5
Global
r=1, w=1
PZD Setpoint Mapping Rx 6. mapped Parameter: Address of the parameter which is
imaged sixth from the contents of the process data channel (receiving direction as seen by the
inverter).
Fieldbus: 1LSB=1; Type: U32; raw value:USS-Adr; USS-Adr: 01 16 80 05 hex
205Ah 5h