Specifications
Table Of Contents
- Cover Sheet
- Table of Contents
- Notes on Safety
- Introduction
- Selecting the Type of Reference Value
- Representing the Reference Values in User Units
- Combining the Reference Values
- Available Reference Values
- Additional Functions
- Parameterizing the Speed and Torque Limits
- Additional Functions
- Fieldbus
- Used Parameters
- Global Presence
- Publication
- STÖBER Homepage
- STÖBER Product Range

Comfort Reference Value – 5th Generation of STÖBER Inverters
STÖBER
ANTRIEBSTECHNIK
11. Used Parameters
KSW-79
A.. Inverter
Par. Description Fieldbus-
address
A80
Global
r=2, w=2
Serial address: Specifies the address of the inverter for serial communication via X3 with
POSITool or another USS master.
Value range: 0 ... 0 ... 31
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 01 14 00 00 hex
2050h 0h
A81
Global
r=1, w=1
Serial baudrate: Starting with V 5.1, writing to A81 no longer changes the baud rate immediately
but now not until after device OFF-ON (previously with A00 save values) or A87 activate serial
baud rate = 1 (activate baud rate).
This makes the reaction identical to that of the fieldbuses.
0: 9600 Baud;
1: 19200 Baud;
2: 38400 Baud;
3: 57600 Baud
;
4: 115200 Baud;
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 01 14 40 00 hex
2051h 0h
A82
Global
r=0, w=0
CAN baudrate: Setting of the baud rate with which the CAN-Bus will be operated. Cf. CAN-Bus
supplementary documentation, publ. no. 441686.
0: 10 kBit/s;
1
: 20 kBit/s;
2: 50 kBit/s;
3: 100 kBit/s;
4: 125 kBit/s;
5: 250 kBit/s;
6: 500 kBit/s;
7: 800 kBit/s;
8: 1000 kBit/s;
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 01 14 80 00 hex
1 Only visible when the CAN 5000 option is installed or when CAN 5000 was selected as option
module 2 in the device configuration.
2052h 0h
A83
Global
r=0, w=0
Busaddress: Specifies the device address for operation with fieldbus. A83 has no effect on
communication via X3 with POSITool or another USS master.
Value range: 0 ... 1 ... 125
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 01 14 C0 00 hex
2053h 0h
A84
Global
read (0)
PROFIBUS baudrate: When operated with a device of the 5th generation of STÖBER inverters
with option board "PROFIBUS DP," the baud rate found on the bus is indicated
. Cf. PROFIBUS
supplementary documentation publ. no. 441687.
0: Not found;
1: 9.6kBit/s;
2: 19.2kBit/s;
3: 45.45kBit/s;
4: 93.75kBit/s;
5: 187.5kBit/s;
6: 500 kBit/s;
7: 1500kBit/s;
8: 3000kBit/s;
9: 6000kBit/s;
10: 12000kBit/s;
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 01 15 00 00 hex
1 Only visible when a PROFIBUS device controller is selected in the device configuration or the
appropriate blocks were used with the option for free, graphic programming.
2054h 0h