Comfort Reference Value – 5th Generation of STÖBER Inverters
STÖBER
ANTRIEBSTECHNIK
9. Additional Functions
KSW-67
9.4 Reference Value Enable
Description
The reference values "external reference value," "correct ref1 and 2," "jog ref value,"
"PID ref value" and "PID actual value" generate a reference value enable. Go to page 12
of the Assistant to activate the evaluation of the reference value enable in D55 (Figure
9-7).
Figure 9-7 Parameterizing the reference value enable
The reference value enables to be used are activated by individual bit:
Bit in D55 Enable of the Reference
Value
Bit 0 Reference value external
Bit 1 Correct ref1
Bit 2 Correct ref2
Bit 3 Jog ref value
Bit 4 PID ref value
Bit 5 PID actual value
The enable of a reference value is active when the applicable bit is active in D55 and the
reference value has reached the value in the related parameter 51.X. The reference
value enable is AND-linked with the signal AdditionalEnable 2 (selector D113, indication
D313). When both signals are active the device enable can be given together with the
hardware enable on X1.
You can use several reference value enables at the same time. If you do, at least one of
the reference value enables must be active.