Specifications

Comfort Reference Value – 5th Generation of STÖBER Inverters
STÖBER
ANTRIEBSTECHNIK
8. Parameterizing the Speed and Torque Limits
KSW-59
Analog signals
Signal Function Selector
Fieldbus
Image
Display
Parameter
Scaling
Max pos. speed,
torque control
Positive speed limit with torque control
D136 D236 D336 -
Max. neg. speed,
torque control
Negative speed limit with torque control
D137 D237 D337 -
Max. pos. speed,
speed control
Positive speed limit with speed control
D138 D238 D338 -
Max. neg. speed,
speed control
Negative speed limit with speed control
D139 D239 D339 -
Signal Function
Fieldbus
Image
Single
Parameter
Standstill
When the signal is high the actual motor speed has reached the value 0 Rpm,
± C40.
D200 Bit0 D180
Reference value
reached
When the signal is high the ramp generator has reached the reference value.
D200 Bit1 D181
Actual value
reached
When the signal is high the motor speed (E91) has reached the reference
specification (E07), ± C40.
D200 Bit9 D183
Reference value
prohibited
When the signal is high a positive or negative reference value is specified
although the applicable direction is disabled (D308 = 1:active or D309 =
1:active).
D200 Bit10 D184
Max. speed limit
reached
When the signal is high the reference value has reached the speed limit which
is specified by the source set in D138.
D200 Bit11 D185
Min. speed limit
reached
When the signal is high the reference value has reached the speed limit which
is specified by the source set in D139.
D200 Bit12 D186
Zero ramp
reached
When the signal is high the ramp generator has reached the value 0.
D200 Bit15 D189
Signal Function
Fieldbus
Image
Single
Parameter
Scan active
When the signal is high the drive is in "scan active" mode as per C20. D201 Bit4 D433
Heavy duty start
When the signal is high the drive is in "heavy duty start" mode as per C20. D201 Bit5 D434
Reference value
ready
The signal is active when the inverter is enabled and the brake is open.
D201 Bit6 D435
Positive torque
active
When the signal is high the current torque (E90) as related to the user
direction (D57) is greater than 5%.
D201 Bit11 D440
Negative torque
active
When the signal is high the current torque (E90) as related to the user
direction (D57) is less than -5%.
D201 Bit12 D441
Forward direction
When the signal is high the speed (E91) as related to the inverted user
direction (D57) is greater than C40.
D201 Bit13 D442
Accelerating When the signal is high the motor speed increases.
D201 Bit14 D443
Decelerating When the signal is high the motor speed decreases.
D201 Bit15 D444