Specifications

Comfort Reference Value – 5th Generation of STÖBER Inverters
STÖBER
ANTRIEBSTECHNIK
8. Parameterizing the Speed and Torque Limits
KSW-58
NOTE
The speed limits can only be set in Rpm (speed of the motor) during torque control. The
display in user units is reserved for scaling the torque or the force.
How to parameterize speed limits
during speed control …
Page 9.3 of the Assistant gives you an overview of the speed limits during speed control.
The positive speed limit is parameterized on page 9.3.1. The negative speed limit is
parameterized on page 9.3.2. To parameterize the speed limit proceed as described
below:
On page 9.3.1 select the source of the positive speed limit in parameter D138 (Figure
8-6). You have a choice of either an analog input or fieldbus operation.
If you selected an analog input further parameters appear which you can use to
parameterize the interface.
If you selected fieldbus operation the parameter is indicated which you will write via
fieldbus.
Go to page 9.3.2 of the Assistant to parameterize the negative speed limit. Proceed as
described for the positive limit.
Figure 8-6 Setting the signal source of the positive speed limit during speed control
NOTE
Limits set in these parameters do not deactivate the speed limit C01. C01 may have to
be adjusted to prevent premature limitation by this parameter.