6. Available Reference Values
KSW-42
NOTE
The characteristic curve for reference value and actual value makes it possible to adjust
different scaled sources to each other. This makes the PID control error independent of
offset and factor reactions of the signal sources.
• Go to page 3.6.1 of the Assistant.
• Set the actual value low pass in G11 (Figure 6-21).
Figure 6-21 Setting the low pass for the actual PID value
The PID control error is calculated from the reference values and the actual values. This
variable is given to the PID controller. You can monitor the value online in the parameter
G180 on page 3.6.1 of the Assistant.