ANTRIEBSTECHNIK
6. Available Reference Values
KSW-34
6.3 Motor Potentiometer
Information that you will find in
this section …
This section gives you information on:
when to use the motor potentiometer
how the motor potentiometer reference value works
and how to set the reference value
When to use the motor
potentiometer …
Use the motor potentiometer when you want to make a digital change in a reference
value. This means that you raise or lower the reference value via binary signals.
Remember that the motor potentiometer reference value is secure against power
failures. This means that the last valid value is still present after power off and power on
unless a reset has been parameterized for power on (D40 bit 0 – for details see next
section).
All the settings for the motor potentiometer are made on page 3.5 of the Assistant
(Figure 6-13).
Figure 6-13 Making the settings for the motor potentiometer