Specifications
Table Of Contents
- Cover Sheet
- Table of Contents
- Notes on Safety
- Introduction
- Selecting the Type of Reference Value
- Representing the Reference Values in User Units
- Combining the Reference Values
- Available Reference Values
- Additional Functions
- Parameterizing the Speed and Torque Limits
- Additional Functions
- Fieldbus
- Used Parameters
- Global Presence
- Publication
- STÖBER Homepage
- STÖBER Product Range

Comfort Reference Value – 5th Generation of STÖBER Inverters
STÖBER
ANTRIEBSTECHNIK
6. Available Reference Values
KSW-33
Binary input signals
Signal Function Selector
Fieldbus
Image
Display
Parameter
Time ON Time OFF
Preset value
select 0
D125.0 D212 Bit3
- -
Preset value
select 1
D125.1 D212 Bit4
- -
Preset value
select 2
The binary-coded switchover between
the preset values takes place with the
preset value select signals 0 to 2.
D125.2 D212 Bit5
D325
- -
Signal Function Selector
Fieldbus
Image
Display
Parameter
Time ON Time OFF
Enable preset
reference value /
preset value
(edge)
After a switchover of the preset
reference values, preset values,
acceleration and deceleration ramps, the
change must be accepted by an enable
signal. This prevents undesired states.
The enable is given when the enable
preset reference value/preset value
(edge) signal has a positive edge or the
enable preset reference value/preset
value (level) signal has a HIGH level.
D128 D212 Bit14 D328 D428.0 D428.1
Enable preset
reference value /
preset value
(level)
D129 D212 Bit15 D329 D429.0 D429.1