How to enter ramp blocks …
Enter the ramps on page 3.4.1 as shown below (Figure 6-8):
Go to page 3.4.1 of the Assistant.
Use the up/down arrow keys to select the ramp block that you want to enter.
Enter the designation of the ramp block (e.g., ramp feed) in parameter D20.x. Enter in
D21.x whether you want symmetric or asymmetric ramps for right or left direction.
When D21.X is set to 1:active the acceleration ramp is specified in D22.x and the
deceleration ramp is specified in D23.x for both directions of rotation. When
D21.x=0:inactive, D22.x and D23.x apply to the right direction. D24.x and D25.x
provide the ramps for acceleration and deceleration for the left direction.
Enter the ramp values (e.g., 150 [rpm/s]) in D22.x to D25.x.
Figure 6-8 View of the ramp profile Assistant
PRV accelerating source select 0
(Selector D126.0)
PRV accelerating source select 1
(Selector D126.1)
Decode
Dir. right/
direction left
Current
accelerating
ramp