Specifications
Table Of Contents
- Cover Sheet
- Table of Contents
- Notes on Safety
- Introduction
- Selecting the Type of Reference Value
- Representing the Reference Values in User Units
- Combining the Reference Values
- Available Reference Values
- Additional Functions
- Parameterizing the Speed and Torque Limits
- Additional Functions
- Fieldbus
- Used Parameters
- Global Presence
- Publication
- STÖBER Homepage
- STÖBER Product Range

Comfort Reference Value – 5th Generation of STÖBER Inverters
STÖBER
ANTRIEBSTECHNIK
11. Used Parameters
KSW-244
Z.. Fault counter
Par. Description Fieldbus-
address
Z60
Global
read (3)
Application event 0: The parameter indicates how frequently event 60:Application event 0 has
occurred.
Event description:
Trigger: Application specific or by free programming option.
Cause: • Can be programmed as desired for each axis separately.
Level: Can be parameterized in system parameters U100.
Acknowledgment: Turn device off/on or programmed acknowledgment.
Other: - Message/warning: Evaluation in 256-msec cycle.
- Fault: Evaluation in parameterizable cycle time (A150). Texts, times and level
can be set in parameter group U.. starting with U100.
Fieldbus: 1LSB=1; Type: U16; USS-Adr: 1A 0F 00 00 hex
523Ch 0h
Z61
Global
read (3)
Application event 1: The parameter indicates how frequently event 61:Application event 1 has
occurred.
Event description:
Trigger: Application specific or by free programming option.
Cause: • Can be programmed as desired for each axis separately.
Level: Can be parameterized in system parameters U110.
Acknowledgment: Turn device off/on or programmed acknowledgment.
Other: - Message/warning: Evaluation in 256-msec cycle.
- Fault: Evaluation in parameterizable cycle time (A150). Texts, times and level
can be set in parameter group U.. starting with U100.
Fieldbus: 1LSB=1; Type: U16; USS-Adr: 1A 0F 40 00 hex
523Dh 0h
Z62
Global
read (3)
Application event 2: The parameter indicates how frequently event 62:Application event 2 has
occurred.
Event description:
Trigger: Application specific or by free programming option.
Cause: • Can be programmed as desired for each axis separately.
Level: Can be parameterized in system parameters U120.
Acknowledgment: Turn device off/on or programmed acknowledgment.
Other: - Message/warning: Evaluation in 256-msec cycle.
- Fault: Evaluation in parameterizable cycle time (A150). Texts, times and level
can be set in parameter group U.. starting with U100.
Fieldbus: 1LSB=1; Type: U16; USS-Adr: 1A 0F 80 00 hex
523Eh 0h
Z63
Global
read (3)
Application event 3: The parameter indicates how frequently event 63:Application event 3 has
occurred.
Event description:
Trigger: Application specific or by free programming option.
Cause: • Can be programmed as desired for each axis separately.
Level: Can be parameterized in system parameters U130.
Acknowledgment: Turn device off/on or programmed acknowledgment.
Other: - Message/warning: Evaluation in 256-msec cycle.
- Fault: Evaluation in parameterizable cycle time (A150). Texts, times and level
can be set in parameter group U.. starting with U100.
Fieldbus: 1LSB=1; Type: U16; USS-Adr: 1A 0F C0 00 hex
523Fh 0h
Z64
Global
read (3)
Application event 4: The parameter indicates how frequently event 64:Application event 4 has
occurred.
Event description:
Trigger: Application specific or by free programming option.
Cause: • Can be programmed as desired for each axis separately.
Level: Can be parameterized in system parameters U140.
Acknowledgment: Turn device off/on or programmed acknowledgment.
Other: - Message/warning: Evaluation in 256-msec cycle.
- Fault: Evaluation in parameterizable cycle time (A150). Texts, times and level
can be set in parameter group U.. starting with U100.
Fieldbus: 1LSB=1; Type: U16; USS-Adr: 1A 10 00 00 hex
5240h 0h