Comfort Reference Value – 5th Generation of STÖBER Inverters
STÖBER
ANTRIEBSTECHNIK
11. Used Parameters
KSW-237
U.. Protection functions
Par. Description Fieldbus-
address
U132
Axis
r=3, w=3
Text application event 3: Indication which appears on the display when the event is triggered.
Default setting: Range 2 upperLim
Fieldbus: Type: Str16; USS-Adr: 15 21 00 00 hex
4884h 0h
U140
Axis
r=3, w=3
Level application event 4: Application-specific event no. 64. Starting with the level
"1:Message," the event number and the text specified in U142 (e.g., "64:My fault") appear on the
display when this event occurs.
0: inactive;
1: Message;
2: Warning;
3: Fault;
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 15 23 00 00 hex
488Ch 0h
U141
Axis
r=3, w=3
Time application event 4: Can only be set when U140=2:Warning. Defines the time during
which the event remains a warning. After this time expires, the device assumes fault status.
Value range in s: 0.00 ... 0,00 ... 63.75
Fieldbus: 1LSB=0,01s; Type: U8; (raw value:2 Bit=1·s); USS-Adr: 15 23 40 00 hex
1 Only when the appropriate event level is parameterized to 2:Warning.
488Dh 0h
U142
Axis
r=3, w=3
Text application event 4: Indication which appears on the display when the event is triggered.
Default setting: currentloop lost
Fieldbus: Type: Str16; USS-Adr: 15 23 80 00 hex
488Eh 0h
U150
Axis
r=3, w=3
Level application event 5: Application-specific event no. 65. Starting with the level
"1:Message," the event number and the text specified in U152 (e.g., "65:My fault") appear on the
display when this event occurs.
0: inactive;
1: Message;
2: Warning;
3: Fault;
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 15 25 80 00 hex
4896h 0h
U151
Axis
r=3, w=3
Time application event 5: Can only be set when U150=2:Warning. Defines the time during
which the event remains a warning. After this time expires, the device assumes fault status.
Value range in s: 0.00 ... 0,00 ... 63.75
Fieldbus: 1LSB=0,01s; Type: U8; (raw value:2 Bit=1·s); USS-Adr: 15 25 C0 00 hex
1 Only when the appropriate event level is parameterized to 2:Warning.
4897h 0h
U152
Axis
r=3, w=3
Text application event 5: Indication which appears on the display when the event is triggered.
Default setting: limit switch
Fieldbus: Type: Str16; USS-Adr: 15 26 00 00 hex
4898h 0h
U160
Axis
r=3, w=3
Level application event 6: Application-specific event no. 66. Starting with level "1:Message,"
the event number and the text specified in U162 (e.g., "66:My fault") appear on the display when
this event occurs.
0: inactive;
1: Message;
2: Warning;
3: Fault;
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 15 28 00 00 hex