Specifications

Comfort Reference Value – 5th Generation of STÖBER Inverters
STÖBER
ANTRIEBSTECHNIK
11. Used Parameters
KSW-236
U.. Protection functions
Par. Description Fieldbus-
address
U110
Axis
r=3, w=3
Level application event1: Application-specific event no. Nr. 61. Starting with the level
"1:Message," the display shows the event number with the text specified in U112 (e.g., "61:My
fault") when this event occurs.
0: inactive;
1: Message;
2: Warning;
3: Fault;
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 15 1B 80 00 hex
486Eh 0h
U111
Axis
r=3, w=3
Time application event 1: Can only be set when U110=2:Warning. Defines the time during
which the event remains a warning. After expiration of this time, the device assumes fault status.
Value range in s: 0.00 ... 0,00 ... 63.75
Fieldbus: 1LSB=0,01s; Type: U8; (raw value:2 Bit=1·s); USS-Adr: 15 1B C0 00 hex
1 Only when the appropriate event level is parameterized to 2:Warning.
486Fh 0h
U112
Axis
r=3, w=3
Text application event 1: Indication which appears on the display when the event is triggered.
Default setting: Range 1 upperLim
Fieldbus: Type: Str16; USS-Adr: 15 1C 00 00 hex
4870h 0h
U120
Axis
r=3, w=3
Level application event 2: Application-specific event no. 62. Starting with the level
"1:Message," the event number and the text specified in U122 (e.g., "62:My fault") appear on the
display when this event occurs.
0: inactive;
1: Message;
2: Warning;
3: Fault;
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 15 1E 00 00 hex
4878h 0h
U121
Axis
r=3, w=3
Time application event 2: Can only be set when U120=2:Warning. Defines the time during
which the event remains a warning. After expiration of this time, the device assumes fault status.
Value range in s: 0.00 ... 0,00 ... 63.75
Fieldbus: 1LSB=0,01s; Type: U8; (raw value:2 Bit=1·s); USS-Adr: 15 1E 40 00 hex
1 Only when the appropriate event level is parameterized to 2:Warning.
4879h 0h
U122
Axis
r=3, w=3
Text application event 2: Indication which appears on the display when the event is triggered.
Default setting: Range 2 lowerLim
Fieldbus: Type: Str16; USS-Adr: 15 1E 80 00 hex
487Ah 0h
U130
Axis
r=3, w=3
Level application event 3: Application-specific event no. 63. Starting with level "1:Message,"
the event number and the text specified in U132 (e.g., "63:My fault") appear on the display when
this event occurs.
0: inactive;
1: Message;
2: Warning;
3: Fault;
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 15 20 80 00 hex
4882h 0h
U131
Axis
r=3, w=3
Time application event 3: Can only be set when U130=2:Warning. Defines the time during
which the event remains a warning. After this time expires, the device assumes fault status.
Value range in s: 0.00 ... 0,00 ... 63.75
Fieldbus: 1LSB=0,01s; Type: U8; (raw value:2 Bit=1·s); USS-Adr: 15 20 C0 00 hex
1 Only when the appropriate event level is parameterized to 2:Warning.
4883h 0h