11. Used Parameters
KSW-233
R.. Production data
Par. Description Fieldbus-
address
R33
Global
read (3)
Maximum motor power: Maximum power which a motor that is operated on this inverter may
have. Represents the upper limit for B11.
Fieldbus: 1LSB=0,001kW; Type: I16; (raw value:1LSB=0,01·kW); USS-Adr: 12 08 40 00 hex
4221h 0h
R34
Global
read (3)
Maximum brakeresistor power: Maximum power which a brake resistor that is connected to
this inverter may have. Represents the upper limit for A22.
Fieldbus: 1LSB=1W; Type: I16; (raw value:1LSB=10·W); USS-Adr: 12 08 80 00 hex
4222h 0h
R35
Global
read (3)
Minimum brakeresistor resistance: Minimum resistance value which a braking resistor
connected to this inverter must have. Represents the lower limit for A21.
Fieldbus: 1LSB=1Ohm; Type: I16; (raw value:32767 = 3277 Ohm); USS-Adr: 12 08 C0 00 hex
4223h 0h
R36.0
Global
read (3)
Hardware-version control-unit for hardware: Number specifying the hardware version of
the control unit. All changes in the hardware states are counted here.
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 12 09 00 00 hex
4224h 0h
R36.1
Global
read (3)
Hardware-version control-unit for software: Number specifying the hardware version of
the control unit. All changes in the hardware states which require a software adjustment are
counted here.
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 12 09 00 01 hex
4224h 1h
T.. Scope
Par. Description Fieldbus-
address
T25
Global
r=3, w=3
Automatic scope start: When T25 is "1:active," Scope starts automatically after the
configuration is downloaded. With a device new start, Scope is also automatically started with the
settings saved last.
0: inactive;
1: active;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 14 06 40 00 hex
4619h 0h
U.. Protection functions
Par. Description Fieldbus-
address
U00
Global
r=3, w=3
Level low voltage: Level at which the event "46:low voltage" is triggered due to cause "1:low
voltage DC link voltage limit."
2: Warning; After the tolerance time in U01 expires, the device assumes fault status.
3: Fault
; When the value in A35 is passed below, the device immediately assumes fault status.
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 15 00 00 00 hex
4800h 0h
U01
Global
r=3, w=3
Time low voltage: Can only be set with U00=2:Warning. Defines the time during which the
triggering of low voltage monitoring is tolerated. After expiration of this time, the device assumes
fault status.
Value range in s: 1.00 ... 1,00 ... 10.00
Fieldbus: 1LSB=0,01s; Type: U8; (raw value:2 Bit=1·s); USS-Adr: 15 00 40 00 hex
1 Only when the appropriate event level is parameterized to 2:Warning.
4801h 0h