Specifications

Comfort Reference Value – 5th Generation of STÖBER Inverters
STÖBER
ANTRIEBSTECHNIK
11. Used Parameters
KSW-224
G.. Technology
Par. Description Fieldbus-
address
15: BE7;
16: BE7-inverted;
17: BE8;
18: BE8-inverted;
19: BE9;
20: BE9-inverted;
21: BE10;
22: BE10-inverted;
23: BE11;
24: BE11-inverted;
25: BE12;
26: BE12-inverted;
27: BE13;
28: BE13-inverted;
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 07 19 80 00 hex
G132
Axis, OFF
r=1, w=1
Source technology reference value: Selection of the source for the "Tech.ref.Value" signal.
The reference value can be supplied by the analog inputs or by the fieldbus. When
G132=4:parameter the parameter G232 is used as the signal source.
0: 0 (zero);
1: AE1;
2: AE2;
3: AE3;
4: parameter;
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 07 21 00 00 hex
2C84h 0h
G133
Axis, OFF
r=1, w=1
Source actual technology value: Selection of the source for the "Tech.ActValue" signal. The
actual value can be supplied by the analog inputs or by the fieldbus. When G133=4:parameter the
parameter G233 is used as the signal source.
0: 0 (zero);
1: AE1;
2: AE2;
3: AE3;
4: parameter;
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 07 21 40 00 hex
2C85h 0h
G180
Axis
read (2)
PID control error: Display parameter for the control error of the PID controller (G180 = G332 -
G333).
Fieldbus: 1LSB=0,1%; PDO ; Type: I16; (raw value:32767·LSB=200,0%); USS-Adr: 07 2D 00 00 hex
2CB4h 0h
G181
Axis
read (1)
PID upper limit: Binary signal, assumes the value "1" when the PID controller reaches the
maximum permissible value (can be set with G08) on the output. In fieldbus mode the signal can be
read for the following status words based on the selected application:
Application Parameter Bit
Technology controller G200 3
Comfort reference value D200 7
0: inactive;
1: active;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 07 2D 40 00 hex
2CB5h 0h
G182
Axis
read (1)
PID lower limit: Binary signal, assumes the value "1" when the PID controller reaches the
minimum permissible value (can be set with G09) on the output. In fieldbus mode the signal can be
read for the following status words based on the selected application:
Application Parameter Bit
Technology controller G200 4
Comfort reference value D200 8
0: inactive;
1: active;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 07 2D 80 00 hex
2CB6h 0h