Specifications

Comfort Reference Value – 5th Generation of STÖBER Inverters
STÖBER
ANTRIEBSTECHNIK
11. Used Parameters
KSW-222
G.. Technology
Par. Description Fieldbus-
address
G97
Global
read (3)
PLL cycle-correction: Cycle correction specified by PLL control.
Fieldbus: 1LSB=1clock-cycles; Type: I8; USS-Adr: 07 18 40 00 hex
2C61h 0h
G98
Global
r=3, w=3
Reference cycle-time: Specified value for the cycle time of the SYNC telegram.
Value range in µs: 0 ... 4000 ... 8000
Fieldbus: 1LSB=1µs; Type: I16; USS-Adr: 07 18 80 00 hex
2C62h 0h
G100
Axis, OFF
r=1, w=1
Source negate technologie reference value: Selection of the source for the
"neg.ref.value" signal.
When G100=2:parameter the control byte or control word is used as the signal source. This setting
should be used for fieldbus operation. The control word can be set to different parameters for
different applications. The list below indicates the control words for the different applications. The
signal can be directly monitored via G300 on the block input.
Application Parameter Bit
Technology controller G210 2
Comfort reference value D211 4
0: Low;
1: High;
2: parameter;
3: BE1;
4: BE1-inverted;
5: BE2;
6: BE2-inverted;
7: BE3;
8: BE3-inverted;
9: BE4;
10: BE4-inverted;
11: BE5;
12: BE5-inverted;
13: BE6;
14: BE6-inverted;
15: BE7;
16: BE7-inverted;
17: BE8;
18: BE8-inverted;
19: BE9;
20: BE9-inverted;
21: BE10;
22: BE10-inverted;
23: BE11;
24: BE11-inverted;
25: BE12;
26: BE12-inverted;
27: BE13;
28: BE13-inverted;
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 07 19 00 00 hex
2C64h 0h