Specifications

Comfort Reference Value – 5th Generation of STÖBER Inverters
STÖBER
ANTRIEBSTECHNIK
11. Used Parameters
KSW-218
F.. Control Interface
Par. Description Fieldbus-
address
18: BE8-inverted;
19: BE9;
20: BE9-inverted;
21: BE10;
22: BE10-inverted;
23: BE11;
24: BE11-inverted;
25: BE12;
26: BE12-inverted;
27: BE13;
28: BE13-inverted;
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 06 19 00 00 hex
F181
Global
read (1)
BA1: Bit 0 from the BA control bits byte F210. In the "comfort reference value" application, the
status of BE1 can be indicated based on F209.
0: Low;
1: High;
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 06 2D 40 00 hex
1 Only when a board is installed in the bottom option slot.
2AB5h 0h
F182
Global
read (1)
BA2: Bit 1 from the BA control bits byte F210. In the "comfort reference value" application, the
status of BE2 can be indicated based on F209.
0: Low;
1: High;
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 06 2D 80 00 hex
1 Only when a board is installed in the bottom option slot.
2AB6h 0h
F183
Global
read (1)
BA3: Bit 2 from the BA control bits byte F210. In the "comfort reference value" application, the
status of BE3 can be indicated based on F209.
0: Low;
1: High;
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 06 2D C0 00 hex
1 Only when an XEA board is installed in the bottom option slot.
2AB7h 0h
F184
Global
read (1)
BA4: Bit 3 from the BA control bits byte F210. In the "comfort reference value" application, the
status of BE4 can be indicated based on F209.
0: Low;
1: High;
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 06 2E 00 00 hex
1 Only when an XEA board is installed in the bottom option slot.
2AB8h 0h
F185
Global
read (1)
BA5: Bit 4 from the BA control bits byte F210. In the "comfort reference value" application, the
status of BE5 can be indicated based on F209.
0: Low;
1: High;
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 06 2E 40 00 hex
1 Only when an XEA board is installed in the bottom option slot.
2AB9h 0h
F186
Global
read (1)
BA6: Bit 5 from the BA control bits byte F210. In the "comfort reference value" application, the
status of BE6 can be indicated based on F209.
0: Low;
1: High;
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 06 2E 80 00 hex
1 Only when an XEA board is installed in the bottom option slot.
2ABAh 0h