11. Used Parameters
KSW-216
F.. Control Interface
Par. Description Fieldbus-
address
F65
Axis
r=2, w=2
BA5-source: The value of the parameterized coordinate is output on binary output 5 (X103.3).
Value range: A00 ... F185 ... A.Gxxx.yyyy (Parameter number in plain text)
Fieldbus: 1LSB=1; Type: U32; raw value:USS-Adr; USS-Adr: 06 10 40 00 hex
1 Only when an XEA board is installed in the bottom option slot.
2A41h 0h
F66
Axis
r=2, w=2
BA6-source: The value of the parameterized coordinate is output on binary output 6 (X103.4).
Value range: A00 ... F186 ... A.Gxxx.yyyy (Parameter number in plain text)
Fieldbus: 1LSB=1; Type: U32; raw value:USS-Adr; USS-Adr: 06 10 80 00 hex
1 Only when an XEA board is installed in the bottom option slot.
2A42h 0h
F67
Axis
r=2, w=2
BA7-source: The value of the parameterized coordinate is output on binary output 7 (X103.5).
Value range: A00 ... F187 ... A.Gxxx.yyyy (Parameter number in plain text)
Fieldbus: 1LSB=1; Type: U32; raw value:USS-Adr; USS-Adr: 06 10 C0 00 hex
1 Only when an XEA board is installed in the bottom option slot.
2A43h 0h
F68
Axis
r=2, w=2
BA8-source: The value of the parameterized coordinate is output on binary output 8 (X103.6).
Value range: A00 ... F188 ... A.Gxxx.yyyy (Parameter number in plain text)
Fieldbus: 1LSB=1; Type: U32; raw value:USS-Adr; USS-Adr: 06 11 00 00 hex
1 Only when an XEA board is installed in the bottom option slot.
2A44h 0h
F69
Axis
r=2, w=2
BA9-source: The value of the parameterized coordinate is output on binary output 9 (X103.7).
Fieldbus: 1LSB=1; Type: U32; raw value:USS-Adr; USS-Adr: 06 11 40 00 hex
1 Only when an XEA board is installed in the bottom option slot.
2A45h 0h
F70
Axis
r=2, w=2
BA10-source: The value of the parameterized coordinate is output on binary output 10 (X103.8).
Fieldbus: 1LSB=1; Type: U32; raw value:USS-Adr; USS-Adr: 06 11 80 00 hex
1 Only when an XEA board is installed in the bottom option slot.
2A46h 0h
F80
Axis
r=2, w=2
BA1 on delay: A signal which is output on BA1 can be delayed with the parameters F80 and
F81. When a value is entered in F80, the switchon procedure of the signal is delayed by this
number of milliseconds.
Value range in ms: 0 ... 0 ... 4294967
Fieldbus: 1LSB=1ms; Type: U32; (raw value:1LSB=0,00099999993131496·ms); USS-Adr: 06 14 00 00 hex
1 Only when a board is installed in the bottom option slot.
2A50h 0h
F81
Axis
r=2, w=2
BA1 off delay: A signal which is output on BA1 can be delayed with the parameters F80 and
F81. When a value is entered in F81, the switchoff procedure of the signal is delayed by this
number of milliseconds.
Value range in ms: 0 ... 0 ... 4294967
Fieldbus: 1LSB=1ms; Type: U32; (raw value:1LSB=0,00099999993131496·ms); USS-Adr: 06 14 40 00 hex
1 Only when a board is installed in the bottom option slot.
2A51h 0h
F82
Axis
r=2, w=2
BA1 inverting: When the parameter F82 is activated, the output of the signal entered in F61 is
inverted on BA1.
0: inactive;
1: active;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 06 14 80 00 hex
1 Only when a board is installed in the bottom option slot.
2A52h 0h