11. Used Parameters
KSW-215
F.. Control Interface
Par. Description Fieldbus-
address
F51
Axis
r=2, w=2
Analog-output2-offset: Offset of the analog output 2. The signal is multiplied by F52. F51 is
then added.
Value range in V: -10.000 ... 0,000 ... 10.000
Fieldbus: 1LSB=0,001V; Type: I16; (raw value:32767 = 20.000 V); USS-Adr: 06 0C C0 00 hex
1 Only when a board is installed in the bottom option slot.
2A33h 0h
F52
Axis
r=2, w=2
Analog-output2-gain: The signal is multiplied by F52. F51 is then added.
Value range in %: -3198.9 ... 100,0 ... 3198.9
Fieldbus: 1LSB=0,1%; Type: I16; (raw value:1024·LSB=100%); USS-Adr: 06 0D 00 00 hex
1 Only when a board is installed in the bottom option slot.
2A34h 0h
F53
Axis
r=2, w=2
Analog-output2-act low pass filter: The time constant for filtering an actual value which was
output on analog output 2 is parameterized in F53.
Value range in ms: 0.0 ... 1,2 ... 200.1
Fieldbus: 1LSB=0,1ms; Type: I32; raw value:1LSB=Fnct.no.11; USS-Adr: 06 0D 40 00 hex
2A35h 0h
F54
Axis
r=2, w=2
Analog-output2-absolut: Generation of the amount for analog output 2 can be activated in
F54. When F54 is set to 1:active, the amount of the parameter entered in F50 is output on analog
output 2.
0: inactive;
1: active;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 06 0D 80 00 hex
2A36h 0h
F61
Axis
r=2, w=2
BA1-source: The value of the parameterized coordinate is output on binary output 1 (X101.8).
NOTE
Please remember that binary output BA1 is already being used by the encoder simulation via the
binary outputs. In this case no entry is permitted in F61.
Value range: A00 ... F181 ... A.Gxxx.yyyy (Parameter number in plain text)
Fieldbus: 1LSB=1; Type: U32; raw value:USS-Adr; USS-Adr: 06 0F 40 00 hex
1 Only when a board is installed in the bottom option slot.
2A3Dh 0h
F62
Axis
r=2, w=2
BA2-source: The value of the parameterized coordinate is output on binary output 2 (X101.9).
NOTE
Please remember that binary output BA2 is already being used by the encoder simulation via the
binary outputs. In this case no entry is permitted in F62.
Value range: A00 ... F182 ... A.Gxxx.yyyy (Parameter number in plain text)
Fieldbus: 1LSB=1; Type: U32; raw value:USS-Adr; USS-Adr: 06 0F 80 00 hex
1 Only when a board is installed in the bottom option slot.
2A3Eh 0h
F63
Axis
r=2, w=2
BA3-source: The value of the parameterized coordinate is output on binary output 1 (X103.1).
Value range: A00 ... F183 ... A.Gxxx.yyyy (Parameter number in plain text)
Fieldbus: 1LSB=1; Type: U32; raw value:USS-Adr; USS-Adr: 06 0F C0 00 hex
1 Only when an XEA board is installed in the bottom option slot.
2A3Fh 0h
F64
Axis
r=2, w=2
BA4-source: The value of the parameterized coordinate is output on binary output 4 (X103.2).
Value range: A00 ... F184 ... A.Gxxx.yyyy (Parameter number in plain text)
Fieldbus: 1LSB=1; Type: U32; raw value:USS-Adr; USS-Adr: 06 10 00 00 hex
1 Only when an XEA board is installed in the bottom option slot.
2A40h 0h