Specifications

Comfort Reference Value – 5th Generation of STÖBER Inverters
STÖBER
ANTRIEBSTECHNIK
11. Used Parameters
KSW-214
F.. Control Interface
Par. Description Fieldbus-
address
F32
Axis
r=2, w=2
AE3-gain: F31 is added to E74. The result is multiplied by F32. This signal is supplied to the
configuration.
Value range in %: -400.0 ... 100,0 ... 400.0
Fieldbus: 1LSB=0,1%; Type: I16; (raw value:32767·LSB=400,0%); USS-Adr: 06 08 00 00 hex
1 Only when an XEA board is installed in the bottom option slot.
2A20h 0h
F33
Axis
r=2, w=2
AE3 ref low pass filter: The time constant for filtering a reference value specified on AE3 is
parameterized in F33.
Value range in ms: 0.0 ... 1,2 ... 200.1
Fieldbus: 1LSB=0,1ms; Type: I32; raw value:1LSB=Fnct.no.11; USS-Adr: 06 08 40 00 hex
1 Only when an XEA board is installed in the bottom option slot.
2A21h 0h
F40
Axis
r=2, w=2
Analog-output1-source: The value of the parameterized coordinates is output on analog output
(X100.6). A voltage of ±10 V is available on the terminals. The resolution is approx. 10 mV. The
scanning time corresponds to A150. Only parameters with the data type "16-bit with sign" can be
used as source (I16, see parameter editor, ±16384=±10 V).
Value range: A00 ... E08 ... A.Gxxx.yyyy (Parameter number in plain text)
Fieldbus: 1LSB=1; Type: U32; raw value:USS-Adr; USS-Adr: 06 0A 00 00 hex
1 Only when a board is installed in the bottom option slot.
2A28h 0h
F41
Axis
r=2, w=2
Analog-output1-offset: Offset of the analog output 1. The signal is multiplied by F42. F41 is
then added.
Value range in V: -10.000 ... 0,000 ... 10.000
Fieldbus: 1LSB=0,001V; Type: I16; (raw value:32767 = 20.000 V); USS-Adr: 06 0A 40 00 hex
1 Only when a board is installed in the bottom option slot.
2A29h 0h
F42
Axis
r=2, w=2
Analog-output1-gain: The signal is multiplied by F42. F41 is then added.
Value range in %: -3198.9 ... 100,0 ... 3198.9
Fieldbus: 1LSB=0,1%; Type: I16; (raw value:1024·LSB=100%); USS-Adr: 06 0A 80 00 hex
1 Only when a board is installed in the bottom option slot.
2A2Ah 0h
F43
Axis
r=2, w=2
Analog-output1-act low pass filter: The time constant for filtering an actual value which was
output on analog output 1 is parameterized in F43.
Value range in ms: 0.0 ... 1,2 ... 200.1
Fieldbus: 1LSB=0,1ms; Type: I32; raw value:1LSB=Fnct.no.11; USS-Adr: 06 0A C0 00 hex
2A2Bh 0h
F44
Axis
r=2, w=2
Analog-output1-absolut: Generation of the amount for analog output 1 can be activated in
F44. When F44 is set to 1:active, the amount of the parameter entered in F40 is output on analog
output 1.
0: inactive;
1: active;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 06 0B 00 00 hex
2A2Ch 0h
F50
Axis
r=2, w=2
Analog-output2-source: The value of the parameterized coordinates is output on analog output
(X100.7). A voltage of ±10 V is available on the terminals. The resolution is approx. 10 mV. The
scanning time corresponds to A150. Only parameters with the data type "16-bit with sign" can be
used as source (I16, see parameter editor, ±16384=±10 V).
Value range: A00 ... E00 ... A.Gxxx.yyyy (Parameter number in plain text)
Fieldbus: 1LSB=1; Type: U32; raw value:USS-Adr; USS-Adr: 06 0C 80 00 hex
1 Only when a board is installed in the bottom option slot.
2A32h 0h