Specifications

Comfort Reference Value – 5th Generation of STÖBER Inverters
STÖBER
ANTRIEBSTECHNIK
11. Used Parameters
KSW-208
E.. Display Value
Par. Description Fieldbus-
address
E100
Global
read (1)
n-motor: Indication of the current motor speed as % in space-saving 16-bit format. The
specification is related to C01 n-max.
Fieldbus: 1LSB=0,1%; PDO ; Type: I16; (raw value:32767·LSB=200,0%); USS-Adr: 05 19 00 00 hex
2864h 0h
E101
Global
read (1)
I-Motor: Indicates the current motor current in % of the nominal device current at 4 kHz switching
frequency.
Fieldbus: 1LSB=1%; PDO ; Type: U8; USS-Adr: 05 19 40 00 hex
2865h 0h
E120
Global
read (1)
Equipment: The text entered in the field "equipment" during step 1/6 of the device configuration.
Fieldbus: Type: Str8; USS-Adr: 05 1E 00 00 hex
2878h 0h
E121
Global
read (1)
User: The text entered in the field "user" during step 1/6 of the device configuration.
Fieldbus: Type: Str16; USS-Adr: 05 1E 40 00 hex
2879h 0h
E122.0
Global
read (3)
Download information: Contains information on the last firmware download.
Fieldbus: Type: Str16; USS-Adr: 05 1E 80 00 hex
287Ah
Array
0h
E122.1
Global
read (3)
Download information: Contains information on the last firmware download.
Fieldbus: Type: Str16; USS-Adr: 05 1E 80 01 hex
287Ah
Array
1h
E122.2
Global
read (3)
Download information: Contains information on the last firmware download.
Fieldbus: Type: Str16; USS-Adr: 05 1E 80 02 hex
287Ah
Array
2h
E122.3
Global
read (3)
Download information: Contains information on the last firmware download.
Fieldbus: Type: Str16; USS-Adr: 05 1E 80 03 hex
287Ah
Array
3h
E149
Global
read (1)
Hardware Version: Device family (FDS/MDS/SDS), hardware version of the power section
(layout version), power section manufacturing date (calendar week and year).
Fieldbus: Type: Str16; USS-Adr: 05 25 40 00 hex
2895h 0h
E151
Global
read (2)
Active switching frequency: The current switching frequency used by the inverter.
Fieldbus: 1LSB=1kHz; Type: U8; USS-Adr: 05 25 C0 00 hex
2897h 0h
E153
Global
read (3)
Accumulated raw-motor-encoder: Supplies an accumulated raw value of the motor encoder
parameterized in B26. The value contains the value of B35 as the adding offset.
Since these values are raw values, scaling depends on the motor encoder being used.
EnDat
®
, SSI: MSB=2048U
Resolver: 65536LSBs=1U (i.e., MSB=32768U)
Incremental encoder: 1LSB=1Count (4-fold evaluation of the number of markers)
MSB = Most Significant Bit
LSB = Least Significant Bit
Fieldbus: 1LSB=1; PDO ; Type: U32; USS-Adr: 05 26 40 00 hex
2899h 0h