Comfort Reference Value – 5th Generation of STÖBER Inverters
STÖBER
ANTRIEBSTECHNIK
11. Used Parameters
KSW-205
E.. Display Value
Par. Description Fieldbus-
address
E80
Axis
read (0)
Operating condition: Indication of the current operating status as per the operating indication.
Useful for fieldbus queries or serial remote control.
10: PLCO_Init;
11: PLCO_Passive;
12: standstill;
13: discrete motion;
14: continuous motion;
15: synchronous motion;
16: stopping;
17: error stop;
18: homing;
19: limit switch;
20: denied;
21: limited;
22: aborted;
23: waiting;
24: delay;
30: fault;
31: self-test;
32: switch-on disable;
33: parametrization lock;
34: quick stop;
35: switched on;
36: jog active;
37: Stop activ;
38: stop;
39: not allowed direction;
40: capturing;
41: load start;
42: accelerating;
43: decelerating;
44: reference > max reference;
45: reference < min reference;
46: zero torque;
47: negative Torque;
48: positive Torque;
49: standstill;
50: forward direction;
51: backward direction;
52: limit switch wrong;
Fieldbus: 1LSB=1; PDO ; Type: U8; USS-Adr: 05 14 00 00 hex
2850h 0h
E81
Global
read (1)
Event level: Indicates whether a current event is queued. The corresponding event type is
indicated in E82. Useful for fieldbus polling or serial remote control.
0: inactive; The event system is inactive. The inverter is in normal operation.
1: Message; A message is queued. Operation continues.
2: Warning; A warning is queued. Operation can be continued until expiration of this event's
warning time (indicated in E83 warning time). Afterwards a fault is triggered.
3: Fault; A fault has occurred. Drive function is disabled.
Fieldbus: 1LSB=1; PDO ; Type: U8; USS-Adr: 05 14 40 00 hex
2851h 0h
E82
Global
read (0)
Event type: Indication of the currently queued event/fault. Useful for fieldbus polling or serial
remote control. The cause is stored in E43 / E44.
30: inactive;
31: Short/ground; The hardware overcurrent switch off is active because the motor demands too
much current from the inverter (interwinding fault, overload).
32: Short/ground internal; During the enabling of the inverter, a short circuit was determined. An
internal device error has probably occurred.
33: Overcurrent; The total motor current exceeds the permissible maximum. Could be acceleration
times are too short or torque limits in C03 and C05 were set incorrectly.
34: Hardware fault; A hardware error has occurred (e.g., in the memory of the control section). See
E43.
2852h 0h