Specifications

Comfort Reference Value – 5th Generation of STÖBER Inverters
STÖBER
ANTRIEBSTECHNIK
11. Used Parameters
KSW-204
E.. Display Value
Par. Description Fieldbus-
address
E68
Global
read (3)
Required optional board 1: Is entered by the POSITool configuration assistant. When the
configuration is transferred via Paramodul to another device, a comparison of E68 and E54 ensures
that all hardware resources are present. If not, the fault "55:option board" is triggered with E43
event cause =7:wrong or missing option board . The fault can then not be acknowledged.
Default setting: CAN 5000
Fieldbus: Type: Str16; USS-Adr: 05 11 00 00 hex
2844h 0h
E69
Global
read (3)
Required optional board 2: Is entered by the POSITool configuration assistant. When the
configuration is transferred via Paramodul to another device, a comparison of E69 and E58 ensures
that all hardware resources are present. If not, the fault "55:option board" is triggered with E43
event cause =7:wrong or missing option board . The fault can then not be acknowledged.
Default setting: SEA 5001
Fieldbus: Type: Str16; USS-Adr: 05 11 40 00 hex
2845h 0h
E70
Global
read (3)
Required Ax5000: Is entered by the POSITool configuration assistant. When the configuration
via Paramodul is transferred to another device, a comparison of E70 with E57 ensures that all
hardware resources are present. If not, the fault "37:n-feedback" (from V5.2: 37:encoder) with E43
event cause=23:Ax5000-n-reference is triggered. The fault can then not be acknowledged.
Default setting: AX 5000
Fieldbus: Type: Str16; USS-Adr: 05 11 80 00 hex
2846h 0h
E71
Global
read (1)
AE1 scale: AE1 signal by offset and gain. E71 = (E10 + F11) * F12.
Fieldbus: 1LSB=0,1%; Type: I16; (raw value:32767·LSB=200,0%); USS-Adr: 05 11 C0 00 hex
2847h 0h
E72
Global
read (1)
AE2 scale: AE2 signal by filter, offset and gain. E72 = (E11 + F21) * F22.
Fieldbus: 1LSB=0,1%; Type: I16; (raw value:32767·LSB=200,0%); USS-Adr: 05 12 00 00 hex
2848h 0h
E73
Global
read (1)
AE3 scale: AE2 signal by filter, offset and gain as well as PID controller and offset 2.
E73 = (E74 + F31) * F32
Fieldbus: 1LSB=0,1%; Type: I16; (raw value:32767·LSB=200,0%); USS-Adr: 05 12 40 00 hex
1 Only when an XEA board is installed in the bottom option slot.
2849h 0h
E74
Global
read (1)
AE3-Level: Level of signal queued on the analog input 3 (X102.1 - X102.2) (without consideration
of F31, F32). To allow for an offset (the value which arrives at the inverter when the controller
specifies 0 V), this must be entered in F31 with the opposite sign.
Fieldbus: 1LSB=0,001V; PDO ; Type: I16; (raw value:32767 = 20.000 V); USS-Adr: 05 12 80 00 hex
1 Only when an XEA board is installed in the bottom option slot.
284Ah 0h