11. Used Parameters
KSW-203
E.. Display Value
Par. Description Fieldbus-
address
E56.2
Global
r=1, w=2
Parameter identification: Indicates whether parameters of the axis 3 were changed via the
operator panel (display and keys). When "0:Axis 1" is selected in A11 Axis Edit and at least one
parameter was changed via the operator panel, the value of E56.0 Parameter identification is set to
255. When"1:Axis 2" is selected in A11, the value of E56.1 is set to 255 if changes were made. The
same also applies to axis 3 and 4. This can be used as an indication of unauthorized manipulation
of parameters.
1: Default setting of POSITool.
2..254: Value was purposely set by the user in POSITool or fieldbus and has not been changed yet.
255: At least one value was changed via the operator panel!
Exceptions: When A11 is set on the operator panel or A00 Save values is triggered, this has no
effect on E56.
Value range: 0 ... 1 ... 255
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 05 0E 00 02 hex
2838h
Array
2h
E56.3
Global
r=1, w=2
Parameter identification: Indicates whether parameters of the axis 4 were changed via the
operator panel (display and keys). When "0:Axis 1" is selected in A11 Axis Edit and at least one
parameter was changed via the operator panel, the value of E56.0 Parameter identification is set to
255. When"1:Axis 2" is selected in A11, the value of E56.1 is set to 255 if changes were made. The
same also applies to axis 3 and 4. This can be used as an indication of unauthorized manipulation
of parameters.
1: Default setting of POSITool.
2..254: Value was purposely set by the user in POSITool or fieldbus and has not been changed yet.
255: At least one value was changed via the operator panel!
Exceptions: When A11 is set on the operator panel or A00 Save values is triggered, this has no
effect on E56.
Value range: 0 ... 1 ... 255
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 05 0E 00 03 hex
2838h
Array
3h
E57
Global
read (1)
POSISwitch: Indication of a POSISwitch
®
which was detected during initialization.
Fieldbus: Type: Str16; USS-Adr: 05 0E 40 00 hex
2839h 0h
E58
Global
read (1)
Optional board 2: Indication of the lower option board (e.g., SEA 5000) which was detected
during initialization.
Fieldbus: Type: Str16; USS-Adr: 05 0E 80 00 hex
283Ah 0h
E59
Global
r=1, w=4
Configuration identification: Indicates the abbreviation for the complete configuration (global
area and all four axes). If the configuration was changed, an asterisk (*) is shown.
Default setting: user
Fieldbus: Type: Str16; USS-Adr: 05 0E C0 00 hex
283Bh 0h
E62
Global
read (1)
Act. pos. T-max: Currently effective positive torque limit in relation to B18.
Fieldbus: 1LSB=0,1%; PDO ; Type: I16; (raw value:32767·LSB=800,0%); USS-Adr: 05 0F 80 00 hex
283Eh 0h
E66
Global
read (1)
Act. neg. T-max: Currently effective positive torque limit in relation to B18.
Fieldbus: 1LSB=0,1%; PDO ; Type: I16; (raw value:32767·LSB=800,0%); USS-Adr: 05 10 80 00 hex
2842h 0h
E67
Global
read (1)
Starting lockout: Indication of the state of the startup-disable option.
0: inactive; The starting lockout (startup disable) is inactive. The power section can be enabled.
1: active; The starting lockout (startup disable) is active. The power section is reliably disabled.
Fieldbus: 1LSB=1; PDO ; Type: B; USS-Adr: 05 10 C0 00 hex
2843h 0h