11. Used Parameters
KSW-202
E.. Display Value
Par. Description Fieldbus-
address
E50
Global
read (0)
Device: Indication of the device type (e.g., MDS 5015).
Fieldbus: Type: Str16; USS-Adr: 05 0C 80 00 hex
2832h 0h
E51
Global
read (0)
Software version: Software version of the inverter (e.g., V5.0).
Fieldbus: Type: Str16; USS-Adr: 05 0C C0 00 hex
2833h 0h
E52
Global
read (1)
Device number: Number of the device from a manufactured series. Corresponds to the number
on the nameplate.
Fieldbus: 1LSB=1; Type: U32; USS-Adr: 05 0D 00 00 hex
2834h 0h
E53
Global
r=1, w=4
Configuration identification global: Indicates the abbreviation for the configuration of the
global area (independent of axis). If the configuration was changed, an asterisk (*) appears.
Default setting: 5:CANopen
Fieldbus: Type: Str16; USS-Adr: 05 0D 40 00 hex
2835h 0h
E54
Global
read (1)
Option board 1: Indication of the upper option board (e.g., CAN 5000) which was detected
during initialization.
Fieldbus: Type: Str16; USS-Adr: 05 0D 80 00 hex
2836h 0h
E55
Axis
r=1, w=4
Configuration identification axis: Indicates the abbreviation for the configuration of the axis.
If the configuration was changed, an asterisk (*) appears.
Default setting: 18:ComfortRV
Fieldbus: Type: Str16; USS-Adr: 05 0D C0 00 hex
2837h 0h
E56.0
Global
r=1, w=2
Parameter identification: Indicates whether parameters of the axis 1 were changed via the
operator panel (display and keys). When "0:Axis 1" is selected in A11 Axis Edit and at least one
parameter was changed via the operator panel, the value of E56.0 Parameter identification is set to
255. When"1:Axis 2" is selected in A11, the value of E56.1 is set to 255 if changes were made. The
same also applies to axis 3 and 4. This can be used as an indication of unauthorized manipulation
of parameters.
1: Default setting of POSITool.
2..254: Value was purposely set by the user in POSITool or fieldbus and has not been changed yet.
255: At least one value was changed via the operator panel!
Exceptions: When A11 is set on the operator panel or A00 Save values is triggered, this has no
effect on E56.
Value range: 0 ... 1 ... 255
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 05 0E 00 00 hex
2838h
Array
0h
E56.1
Global
r=1, w=2
Parameter identification: Indicates whether parameters of the axis 2 were changed via the
operator panel (display and keys). When "0:Axis 1" is selected in A11 Axis Edit and at least one
parameter was changed via the operator panel, the value of E56.0 Parameter identification is set to
255. When"1:Axis 2" is selected in A11, the value of E56.1 is set to 255 if changes were made. The
same also applies to axis 3 and 4. This can be used as an indication of unauthorized manipulation
of parameters.
1: Default setting of POSITool.
2..254: Value was purposely set by the user in POSITool or fieldbus and has not been changed yet.
255: At least one value was changed via the operator panel!
Exceptions: When A11 is set on the operator panel or A00 Save values is triggered, this has no
effect on E56.
Value range: 0 ... 1 ... 255
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 05 0E 00 01 hex
2838h
Array
1h