11. Used Parameters
KSW-199
E.. Display Value
Par. Description Fieldbus-
address
E35
Global
read (1)
Tmin-memorized value: The temperature of the inverter is monitored continuously. The
smallest measured value is stored here non-volatilely. This value can be reset with A37→1.
Fieldbus: 1LSB=1°C; PDO ; Type: I16; (raw value:32767 = 328 °C); USS-Adr: 05 08 C0 00 hex
2823h 0h
E36
Global
read (1)
Tmax-memorized value: The temperature of the inverter is monitored continuously. The
greatest measured value is stored here non-volatilely. This value can be reset with A37→1.
Fieldbus: 1LSB=1°C; PDO ; Type: I16; (raw value:32767 = 328 °C); USS-Adr: 05 09 00 00 hex
2824h 0h
E39
Global
read (3)
Application start time: When the configuration has started successfully on the device, E30
operating time is copied to E39.
Fieldbus: 1LSB=1; Type: U32; USS-Adr: 05 09 C0 00 hex
2827h 0h
E40
Global
r=3, w=4
Temperature counter: This parameter shows the time in % during which the inverter was
operated above a device temperature of 75°C (as measured by the device sensor). The maximum
permissible time is 1 hour (= 100%) within an operating time of 24 hours.
The counter counts up by 0.1% in 3.6 sec and down by 0.1% in 83 sec (i.e., 23 times slower).
Fieldbus: 1LSB=0,1%; Type: U32; (raw value:4294967295·LSB=1327914,6%); USS-Adr: 05 0A 00 00 hex
2828h 0h
E43
Global
read (3)
Event cause: Diagnostic information concerning the fault which occurred last.
Event "34:Hardware fault"
1: Fault while loading the FPGA block to the control section.
2: The non-volatile memory of the control section board is defective.
3: The non-volatile memory of the power section board is defective.
10: The power section serial number does not match the request in control section.
11: Deviation in current offset measurement during device startup is too great.
Event "37:n-feedback"
1: Para <-> encoder; parameterization does not match the connected encoder.
2: ParaChgOffOn; Parameterchange; encoder parameterization cannot be changed during
operation. Save and then turn device off and on so that the change takes effect.
4: Chan.A/Clk; wire break, track A / clock
5: Chan.B/Dat; wire break, track B / data
6: Chan.0; wire break, track 0
7: EnDatAlarm; The EnDat
®
encoder reported an alarm.
8: EnDatCRC; The EnDat
®
encoder reported that too many errors were found during the
redundancy check. The cause can be wirebreak or errors in the cable shield.
9: Comm. offset; commutating offset is not correct.
10: Resol.carrier; resolver is not or wrong connected, wirebreak is possible
11: Resol.undervolt.; wrong transmission factor
12: Resol.overvolt.; wrong transmission factor
13: Resol.parameter;
14: Resol.failure; wirebreak
15: X120-double tr.; Different values were determined during the double transmission to X120.
16: X120-Busy; encoder gave no response for too long; For SSI slave: No telegram for the last 5
ms and drive is enabled.
17: X120-wirebreak;
18: X120-Timeout;
19: X4-double tr.; Different values were determined during the double transmission to X4.
20: X4-Busy; encoder gave no response for too long
21: X4-wirebreak;
22: AX5000; Acknowledgment of the axis switch is not effected.
23: Ax5000required; comparison of E57 and E70.
24: X120-speed; B297, G297 or I297 exceeded.
25: X4-speed; B297, G297 or I297 exceeded.
26: No Enc. found; either no encoder was found on X4 or the EnDat
®
/SSI encoder has a wire
break.
27: AX5000 found; a functional AX 5000 option board was found on X4 although incremental
encoder or EnDat
®
encoder was parameterized, or no EnDat
®
encoder is connected to the AX
5000 option board.
28: EnDat found.; an EnDat
®
encoder was found on X4 although another encoder was
parameterized.
282Bh 0h