11. Used Parameters
KSW-195
D.. Reference Value
Par. Description Fieldbus-
address
D442
Axis
read (1)
Forward direction: When the level is high, the velocity (E91) is greater than C40 in relation to
the user direction (D57). In fieldbus mode the signal can be scanned in D201 Bit13.
0: inactive;
1: active;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 04 6E 80 00 hex
27BAh 0h
D443
Axis
read (1)
Accelerating: When the level is high, the motor speed increases. In fieldbus mode the signal can
be scanned in D201 Bit14.
0: inactive;
1: active;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 04 6E C0 00 hex
27BBh 0h
D444
Axis
read (1)
Decelerating: When the level is high, the motor speed decreases. In fieldbus mode the signal
can be scanned in D201 Bit15.
0: inactive;
1: active;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 04 6F 00 00 hex
27BCh 0h
D445
Axis
read (1)
Torque control: If parameter D445 is 1:active, the inverter is in torque control.
0: inactive;
1: active;
Fieldbus: 1LSB=1; PDO ; Type: B; USS-Adr: 04 6F 40 00 hex
27BDh 0h
D460
Axis
read (1)
Event A active: When the level is high, the event queried via D90 has occurred. In fieldbus
mode the signal can be scanned in D202 Bit11.
0: inactive;
1: active;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 04 73 00 00 hex
27CCh 0h
D461
Axis
read (1)
Event B active: When the level is high, the event queried via D91 has occurred. In fieldbus
mode the signal can be scanned in D202 Bit12.
0: inactive;
1: active;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 04 73 40 00 hex
27CDh 0h
D462
Axis
read (1)
Limit switch active: When the level is high, one of the limit switches has tripped (D303 or
D304). In fieldbus mode the signal can be scanned in D202 Bit13.
0: inactive;
1: active;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 04 73 80 00 hex
27CEh 0h
D463
Axis
read (1)
Warning active: When the level is high, a warning has been determined (E81 = 2).
In fieldbus mode the signal can be scanned in D202 Bit14.
0: inactive;
1: active;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 04 73 C0 00 hex
27CFh 0h
D464
Axis
read (1)
Switch on inhibit: When the level is high, the inverter is in the device state "switch on inhibit"
(E48 = 1). Im Feldbusbetrieb kann das Signal in D202 Bit 15 abgefragt werden.
In fieldbus mode the signal can be scanned in D202 Bi15.
0: inactive;
1: active;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 04 74 00 00 hex
27D0h 0h