Specifications

Comfort Reference Value – 5th Generation of STÖBER Inverters
STÖBER
ANTRIEBSTECHNIK
11. Used Parameters
KSW-193
D.. Reference Value
Par. Description Fieldbus-
address
D420.1
Axis
r=2, w=2
Level enable main ref val delay
Value range in ms: 0 ... 0 ... 4294967
Fieldbus: 1LSB=1ms; Type: U32; (raw value:1LSB=0,00099999993131496·ms); USS-Adr: 04 69 00 01 hex
27A4h
Array
1h
D428.0
Axis
r=2, w=2
Edge enable PR/FR delay: When the signal edge enable PR/FR delay is to be processed with
time delay, a switchon delay can be parameterized in D428.0 and a switchoff delay can be
parameterized in D428.1. The time is specified in ms.
NOTE
Remember that the delay time may be up to one inverter cycle longer (A150). This happens when
the delay is in the range of the inverter cycle time A150.
Value range in ms: 0 ... 0 ... 4294967
Fieldbus: 1LSB=1ms; Type: U32; (raw value:1LSB=0,00099999993131496·ms); USS-Adr: 04 6B 00 00 hex
27ACh
Array
0h
D428.1
Axis
r=2, w=2
Edge enable PR/FR delay
Value range in ms: 0 ... 0 ... 4294967
Fieldbus: 1LSB=1ms; Type: U32; (raw value:1LSB=0,00099999993131496·ms); USS-Adr: 04 6B 00 01 hex
27ACh
Array
1h
D429.0
Axis
r=2, w=2
Level enable PR/FR delay: When the signal level enable PR/FR delay is to be processed with
time delay, a switchon delay can be parameterized in D429.0 and a switchoff delay can be
parameterized in D429.1. The time is specified in ms.
NOTE
Remember that the delay time may be up to one inverter cycle longer (A150). This happens when
the delay is in the range of the inverter cycle time A150.
Value range in ms: 0 ... 0 ... 4294967
Fieldbus: 1LSB=1ms; Type: U32; (raw value:1LSB=0,00099999993131496·ms); USS-Adr: 04 6B 40 00 hex
27ADh
Array
0h
D429.1
Axis
r=2, w=2
Level enable PR/FR delay
Value range in ms: 0 ... 0 ... 4294967
Fieldbus: 1LSB=1ms; Type: U32; (raw value:1LSB=0,00099999993131496·ms); USS-Adr: 04 6B 40 01 hex
27ADh
Array
1h
D430
Axis
read (1)
Actual val direction: D430 shows the direction which is specified at the end of the reference
value path. Inversion of the motor direction by D57 has no effect on D430. This is used here to
indicate the direction in the user representation. The status bit is queried via fieldbus in D201 Bit1.
0: positive;
1: negative;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 04 6B 80 00 hex
27AEh 0h
D431
Axis
read (1)
Brake open: D431 is 1:active when the brake is open. The parameter becomes 0:inactive when
the brake begins to close. Die The status bit is queried via fieldbus in D201 Bit2.
NOTE
The parameter is only written when F08 > 0.
0: inactive;
1: active;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 04 6B C0 00 hex
27AFh 0h
D432
Axis
read (1)
Brake closed: D432 is 1:active when the brake is closed. The parameter becomes 0:inactive
when the brake begins to open. Die The status bit is queried via fieldbus in D201 Bit3.
NOTE
The parameter is only written when F08 > 0.
0: inactive;
1: active;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 04 6C 00 00 hex
27B0h 0h