Specifications

Comfort Reference Value – 5th Generation of STÖBER Inverters
STÖBER
ANTRIEBSTECHNIK
11. Used Parameters
KSW-191
D.. Reference Value
Par. Description Fieldbus-
address
D409.1
Axis
r=2, w=2
Neg. direction blocking delay
Value range in ms: 0 ... 0 ... 4294967
Fieldbus: 1LSB=1ms; Type: U32; (raw value:1LSB=0,00099999993131496·ms); USS-Adr: 04 66 40 01 hex
2799h
Array
1h
D410.0
Axis
r=2, w=2
Torque switch delay: When the signal torque switch delay is to be processed with time delay,
a switchon delay can be parameterized in D410.0 and a switchoff delay can be parameterized in
D410.1.
NOTE
Remember that the delay time may be up to one inverter cycle longer (A150). This happens when
the delay is in the range of the inverter cycle time A150.
Value range in ms: 0 ... 0 ... 4294967
Fieldbus: 1LSB=1ms; Type: U32; (raw value:1LSB=0,00099999993131496·ms); USS-Adr: 04 66 80 00 hex
279Ah
Array
0h
D410.1
Axis
r=2, w=2
Torque switch delay
Value range in ms: 0 ... 0 ... 4294967
Fieldbus: 1LSB=1ms; Type: U32; (raw value:1LSB=0,00099999993131496·ms); USS-Adr: 04 66 80 01 hex
279Ah
Array
1h
D411.0
Axis
r=2, w=2
Master / slave switch delay: When the signal master / slave switch delay is to be processed
with time delay, a switchon delay can be parameterized in D411.0 and a switchoff delay can be
parameterized in D411.1.
The time is specified in ms.
NOTE
Remember that the delay time may be up to one inverter cycle longer (A150). This happens when
the delay is in the range of the inverter cycle time A150.
Value range in ms: 0 ... 0 ... 4294967
Fieldbus: 1LSB=1ms; Type: U32; (raw value:1LSB=0,00099999993131496·ms); USS-Adr: 04 66 C0 00 hex
279Bh
Array
0h
D411.1
Axis
r=2, w=2
Master / slave switch delay
Value range in ms: 0 ... 0 ... 4294967
Fieldbus: 1LSB=1ms; Type: U32; (raw value:1LSB=0,00099999993131496·ms); USS-Adr: 04 66 C0 01 hex
279Bh
Array
1h
D412.0
Axis
r=2, w=2
Speed / torque switch delay: When the signal speed / torque switch delay is to be processed
with time delay, a switchon delay can be parameterized in D412.0 and a switchoff delay can be
parameterized in D412.1.
NOTE
Remember that the delay time may be up to one inverter cycle longer (A150). This happens when
the delay is in the range of the inverter cycle time A150.
Value range in ms: 0 ... 0 ... 4294967
Fieldbus: 1LSB=1ms; Type: U32; (raw value:1LSB=0,00099999993131496·ms); USS-Adr: 04 67 00 00 hex
279Ch
Array
0h
D412.1
Axis
r=2, w=2
Speed / torque switch delay
Value range in ms: 0 ... 0 ... 4294967
Fieldbus: 1LSB=1ms; Type: U32; (raw value:1LSB=0,00099999993131496·ms); USS-Adr: 04 67 00 01 hex
279Ch
Array
1h
D413.0
Axis
r=2, w=2
Additional enable 2 delay: When the signal additional enable 2 delay is to be processed with
time delay, a switchon delay can be parameterized in D413.0 and a switchoff delay can be
parameterized in D413.1. The time is specified in ms.
NOTE
Remember that the delay time may be up to one inverter cycle longer (A150). This happens when
the delay is in the range of the inverter cycle time A150.
Value range in ms: 0 ... 0 ... 4294967
Fieldbus: 1LSB=1ms; Type: U32; (raw value:1LSB=0,00099999993131496·ms); USS-Adr: 04 67 40 00 hex
279Dh
Array
0h