Comfort Reference Value – 5th Generation of STÖBER Inverters
STÖBER
ANTRIEBSTECHNIK
11. Used Parameters
KSW-190
D.. Reference Value
Par. Description Fieldbus-
address
D403.1
Axis
r=2, w=2
Limit switch+ delay
Value range in ms: 0 ... 0 ... 4294967
Fieldbus: 1LSB=1ms; Type: U32; (raw value:1LSB=0,00099999993131496·ms); USS-Adr: 04 64 C0 01 hex
2793h
Array
1h
D404.0
Axis
r=2, w=2
Limit switch- delay: When the signal limit switch- delay is to be processed with time delay, a
switchon delay can be parameterized in D404.0 and a switchoff delay can be parameterized in
D404.1.
The time is specified in ms.
NOTE
Remember that the delay time may be up to one inverter cycle longer (A150). This happens when
the delay is in the range of the inverter cycle time A150.
Value range in ms: 0 ... 0 ... 4294967
Fieldbus: 1LSB=1ms; Type: U32; (raw value:1LSB=0,00099999993131496·ms); USS-Adr: 04 65 00 00 hex
2794h
Array
0h
D404.1
Axis
r=2, w=2
Limit switch- delay
Value range in ms: 0 ... 0 ... 4294967
Fieldbus: 1LSB=1ms; Type: U32; (raw value:1LSB=0,00099999993131496·ms); USS-Adr: 04 65 00 01 hex
2794h
Array
1h
D405.0
Axis
r=2, w=2
Jog enable delay: When the signal jog enable delay is to be processed with time delay, a
switchon delay can be parameterized in D405.0 and a switchoff delay can be parameterized in
D405.1.
NOTE
Remember that the delay time may be up to one inverter cycle longer (A150). This happens when
the delay is in the range of the inverter cycle time A150.
Value range in ms: 0 ... 0 ... 4294967
Fieldbus: 1LSB=1ms; Type: U32; (raw value:1LSB=0,00099999993131496·ms); USS-Adr: 04 65 40 00 hex
2795h
Array
0h
D405.1
Axis
r=2, w=2
Jog enable delay
Value range in ms: 0 ... 0 ... 4294967
Fieldbus: 1LSB=1ms; Type: U32; (raw value:1LSB=0,00099999993131496·ms); USS-Adr: 04 65 40 01 hex
2795h
Array
1h
D408.0
Axis
r=2, w=2
Pos. direction blocking delay: When the signal pos. direction blocking delay is to be
processed with time delay, a switchon delay can be parameterized in D408.0 and a switchoff delay
can be parameterized in D408.1.
The time is specified in ms.
NOTE
Remember that the delay time may be up to one inverter cycle longer (A150). This happens when
the delay is in the range of the inverter cycle time A150.
Value range in ms: 0 ... 0 ... 4294967
Fieldbus: 1LSB=1ms; Type: U32; (raw value:1LSB=0,00099999993131496·ms); USS-Adr: 04 66 00 00 hex
2798h
Array
0h
D408.1
Axis
r=2, w=2
Pos. direction blocking delay
Value range in ms: 0 ... 0 ... 4294967
Fieldbus: 1LSB=1ms; Type: U32; (raw value:1LSB=0,00099999993131496·ms); USS-Adr: 04 66 00 01 hex
2798h
Array
1h
D409.0
Axis
r=2, w=2
Neg. direction blocking delay: When the signal neg. direction blocking delay is to be
processed with time delay, a switchon delay can be parameterized in D409.0 and a switchoff delay
can be parameterized in D409.1.
The time is specified in ms.
NOTE
Remember that the delay time may be up to one inverter cycle longer (A150). This happens when
the delay is in the range of the inverter cycle time A150.
Value range in ms: 0 ... 0 ... 4294967
Fieldbus: 1LSB=1ms; Type: U32; (raw value:1LSB=0,00099999993131496·ms); USS-Adr: 04 66 40 00 hex
2799h
Array
0h