Specifications

Comfort Reference Value – 5th Generation of STÖBER Inverters
STÖBER
ANTRIEBSTECHNIK
11. Used Parameters
KSW-186
D.. Reference Value
Par. Description Fieldbus-
address
D375
Axis
read (2)
Pre val dec ramp selected: The parameter shows the number of the selected preset-
reference-value-decelerating-ramp.
Fieldbus: 1LSB=1; PDO ; Type: U8; USS-Adr: 04 5D C0 00 hex
2777h 0h
D376
Axis
read (2)
Pre val dec ramp actual: The parameter shows the number of the active preset-reference-
value-decelerating-ramp. The decelerating ramp becomes active when the value of the current
preset reference value is reached. The decelerating ramp of the last valid preset reference value is
considered valid as long as this value has not yet been reached.
Fieldbus: 1LSB=1; PDO ; Type: U8; USS-Adr: 04 5E 00 00 hex
2778h 0h
D377
Axis
read (2)
Ramp selected symmetrical: The parameter indicates whether the active preset reference
value is using symmetrical ramps for the clockwise and counterclockwise directions (D21.x). When
the indication is 0:inactive, different ramps are being used for the clockwise and counterclockwise
directions. When the parameter is 1:active, symmetrical ramps are being used.
0: inactive;
1: active;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 04 5E 40 00 hex
2779h 0h
D378
Axis
read (2)
Pre val dec ramp value: The parameter shows the value of the active preset-reference-value-
decelerating-ramp.
NOTE
This parameter is indicated in user units per second. The user units are specified in D87 and D88.
Fieldbus: 1LSB=siehe D86; PDO ; Type: I32; raw value:1LSB=Fnct.no.18; USS-Adr: 04 5E 80 00 hex
277Ah 0h
D380
Axis
read (2)
Motorised pot reference: The parameter shows the current value of the motorized pot
reference value.
NOTE
This parameter is shown in user units. The user units are specified in D87 and D88.
Fieldbus: 1LSB=siehe D86; PDO ; Type: I32; raw value:1LSB=Fnct.no.17; USS-Adr: 04 5F 00 00 hex
277Ch 0h
D381
Axis
read (2)
Main ref value actual: The parameters D381 to D388 show the reference values within the
reference value chain. The parameter shows the value of the active main reference value.
NOTE
This parameter is shown in user units. The user units are specified in D87 and D88.
Fieldbus: 1LSB=siehe D86; PDO ; Type: I32; raw value:1LSB=Fnct.no.17; USS-Adr: 04 5F 40 00 hex
277Dh 0h
D382
Axis
read (2)
Ref val after addition: The parameters D381 to D388 show the reference values within the
reference value chain. The parameter shows the current value after addition of main reference
value D381 and additional reference value.
NOTE
This parameter is shown in user units. The user units are specified in D87 and D88.
Fieldbus: 1LSB=siehe D86; PDO ; Type: I32; raw value:1LSB=Fnct.no.17; USS-Adr: 04 5F 80 00 hex
277Eh 0h
D383
Axis
read (2)
Ref val after multiplying: The parameters D381 to D388 show the reference values within the
reference value chain. The parameter shows the current reference value after multiplication of the
factor reference value with the result of the addition of the main reference value and additional
reference value (D382).
NOTE
This parameter is shown in user units. The user units are specified in D87 and D88.
Fieldbus: 1LSB=siehe D86; PDO ; Type: I32; raw value:1LSB=Fnct.no.17; USS-Adr: 04 5F C0 00 hex
277Fh 0h