Comfort Reference Value – 5th Generation of STÖBER Inverters
STÖBER
ANTRIEBSTECHNIK
11. Used Parameters
KSW-184
D.. Reference Value
Par. Description Fieldbus-
address
D332
Axis
read (2)
Reference value external: Indication of the signal reference value external regardless of the
source selected in D132.
NOTE
This parameter is shown in user units. The user units are specified in D87 and D88.
Fieldbus: 1LSB=siehe D86; PDO ; Type: I32; raw value:1LSB=Fnct.no.17; USS-Adr: 04 53 00 00 hex
274Ch 0h
D333
Axis
read (2)
Correktion ref value 1: Indication of the signal correktion ref value 1 regardless of the source
selected in D133.
NOTE
This parameter is shown in user units. The user units are specified in D87 and D88.
Fieldbus: 1LSB=siehe D86; PDO ; Type: I32; raw value:1LSB=Fnct.no.17; USS-Adr: 04 53 40 00 hex
274Dh 0h
D334
Axis
read (2)
Correktion ref value 2: Indication of the signal correktion ref value 2 regardless of the source
selected in D134.
NOTE
This parameter is shown in user units. The user units are specified in D87 and D88.
Fieldbus: 1LSB=siehe D86; PDO ; Type: I32; raw value:1LSB=Fnct.no.17; USS-Adr: 04 53 80 00 hex
274Eh 0h
D335
Axis
read (2)
Jog ref value: Indication of the signal jog ref value regardless of the source selected in D135.
NOTE
This parameter is shown in user units. The user units are specified in D87 and D88.
Fieldbus: 1LSB=siehe D86; PDO ; Type: I32; raw value:1LSB=Fnct.no.17; USS-Adr: 04 53 C0 00 hex
274Fh 0h
D336
Axis
read (2)
Max V+ torque control: Indication of the signal max V+ torque control regardless of the source
selected in D136.
NOTE
This parameter is shown in user units. The user units are specified in D87 and D88.
Fieldbus: 1LSB=1rpm; PDO ; Type: I32; (raw value:14 Bit=1·rpm); USS-Adr: 04 54 00 00 hex
2750h 0h
D337
Axis
read (2)
Max V- torque control: Indication of the signal max V- torque control regardless of the source
selected in D137.
NOTE
This parameter is shown in user units. The user units are specified in D87 and D88.
Fieldbus: 1LSB=1rpm; PDO ; Type: I32; (raw value:14 Bit=1·rpm); USS-Adr: 04 54 40 00 hex
2751h 0h
D338
Axis
read (2)
Max V+ speed control: Indication of the signal max V+ speed control regardless of the source
selected in D138.
NOTE
This parameter is shown in user units. The user units are specified in D87 and D88.
Fieldbus: 1LSB=siehe D86; PDO ; Type: I32; raw value:1LSB=Fnct.no.17; USS-Adr: 04 54 80 00 hex
2752h 0h
D339
Axis
read (2)
Max V- speed control: Indication of the signal max V- speed control regardless of the source
selected in D139.
NOTE
This parameter is shown in user units. The user units are specified in D87 and D88.
Fieldbus: 1LSB=siehe D86; PDO ; Type: I32; raw value:1LSB=Fnct.no.17; USS-Adr: 04 54 C0 00 hex
2753h 0h
D340
Axis
read (2)
Master reference: Indication of the signal master reference regardless of the source selected in
D140.
NOTE
The reference value is specified as a percentage for each source. This reference value is indicated
in D340 as related to D56.
Fieldbus: 1LSB=0,1%; PDO ; Type: I16; (raw value:32767·LSB=200,0%); USS-Adr: 04 55 00 00 hex
2754h 0h