Comfort Reference Value – 5th Generation of STÖBER Inverters
STÖBER
ANTRIEBSTECHNIK
11. Used Parameters
KSW-183
D.. Reference Value
Par. Description Fieldbus-
address
D324
Axis
read (2)
Preset ref selected: Indication of the signals preset ref selected 0 to 3 as U8 parameters (in
decimal representation).
A preset reference value is selected (binary-coded) with the signals preset ref selected 0 to 3.
Fieldbus: 1LSB=1; PDO ; Type: U8; USS-Adr: 04 51 00 00 hex
2744h 0h
D325
Axis
read (2)
Fix ref selected: Indication of the signals fix ref selected 0 to 2 as U8 parameters (in decimal
representation).
A fix reference value is selected (binary-coded) with the signals fix ref selected 0 to 2.
Fieldbus: 1LSB=1; PDO ; Type: U8; USS-Adr: 04 51 40 00 hex
2745h 0h
D326
Axis
read (2)
Preset ref acc selected: Indication of the signals preset ref acc select 0 to 3 as U8 parameters
(Bit0 = preset ref acc select 0, Bit1 = preset ref acc select 1, Bit2 = preset ref acc select 2, Bit3 =
preset ref acc select 3).
When the parameter D13 is set to 2:binary signals, an acceleration ramp is selected with the
signals preset ref acc selected 0 to 3.
Fieldbus: 1LSB=1; PDO ; Type: U8; USS-Adr: 04 51 80 00 hex
2746h 0h
D327
Axis
read (2)
Preset ref dec selected: Indication of the signals preset ref dec select 0 to 3 as U8
parameters (Bit0 = preset ref dec select 0, Bit1 = preset ref dec select 1, Bit2 = preset ref dec select
2, Bit3 = preset ref dec select 3).
When the parameter D13 is set to 2:binary signals, a decelerating ramp is selected with the signals
preset ref dec selected 0 to 3.
Fieldbus: 1LSB=1; PDO ; Type: U8; USS-Adr: 04 51 C0 00 hex
2747h 0h
D328
Axis
read (2)
Edge enable PR/FR: Indication of the signal edge enable PR/FR regardless of the source
selected in D128.
After a switchover of the preset reference values, fixed values, and accelerating or decelerating
ramps, the change must be accepted with an enable signal. The enable is given when either a
positive edge is determined for the signal edge enable PR/FR or a HIGH level is determined for the
signal level enable PR/FR.
0: inactive;
1: active;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 04 52 00 00 hex
2748h 0h
D329
Axis
read (2)
Level enable PR/FR: Indication of the signal level enable PR/FR regardless of the source
selected in D129.
After a switchover of the preset reference values, fixed values, and accelerating or decelerating
ramps, the change must be accepted with an enable signal. The enable is given when either a
positive edge is determined for the signal edge enable PR/FR or a HIGH level is determined for the
signal level enable PR/FR.
0: inactive;
1: active;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 04 52 40 00 hex
2749h 0h
D330
Axis
read (2)
n-reference value relative: Indicator parameter for the current signal value on the input of the
speed block (RVrelat.). D330 shows the value regardless of the source selected in D130.
When weighted with D02, this signal provides one component of the speed reference value. The
high-resolution speed reference value (RefVal) is then added to this.
Fieldbus: 1LSB=0,1%; PDO ; Type: I16; (raw value:32767·LSB=200,0%); USS-Adr: 04 52 80 00 hex
274Ah 0h
D331
Axis
read (2)
n-reference value high resolution: Indicator parameter for the current signal value on the
input of the quick reference value block (RefVal).
The value of D331 is added to the relative reference value.
Fieldbus: 1LSB=0,001rpm; PDO ; Type: I32; (raw value:14 Bit=1·rpm); USS-Adr: 04 52 C0 00 hex
274Bh 0h