11. Used Parameters
KSW-182
D.. Reference Value
Par. Description Fieldbus-
address
D314
Axis
read (2)
Motorised pot up: Indication of the signal motorised pot up regardless of the source selected in
D114.
A HIGH level of the signal motorized pot up increases the motorized pot reference value in steps or
continuously based on D43.
0: inactive;
1: active;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 04 4E 80 00 hex
273Ah 0h
D315
Axis
read (2)
Motorised pot down: Indication of the signal motorised pot down regardless of the source
selected in D115.
A HIGH level of the signal motorized pot down decreases the motorized pot reference value in
steps or continuously based on D43.
0: inactive;
1: active;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 04 4E C0 00 hex
273Bh 0h
D316
Axis
read (2)
Motorised pot mode: Indication of the signal motorised pot mode regardless of the source
selected in D116.
A HIGH level of the signal motorized pot mode resets the motorized pot reference value to the
value entered in D44.
0: inactive;
1: active;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 04 4F 00 00 hex
273Ch 0h
D317
Axis
read (2)
Motorized pot ramp: When D40 Bit7 is active, the signal motorized pot ramp can be used to
switch between D41 and D42. When the level is low, D41 is used. When the level is high, the ramp
D42 is used.
D317 shows the signal regardless of the source selected in D117.
0: inactive;
1: active;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 04 4F 40 00 hex
273Dh 0h
D318
Axis
read (2)
Main ref select: Indication of the signals main ref select 0 to 2 (D118.x) as U8 parameters (Bit0
= main ref select 0, Bit1 = main ref select 1, Bit2 = main ref select 2). Various main reference value
sources can be selected during operation with the main reference value select signals (e.g.,
reference value, correction reference value or motorized potentiometer). The selection with the
main reference value selectors takes precedence over the setting in D30.
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 04 4F 80 00 hex
273Eh 0h
D319
Axis
read (2)
Edge enable main ref value: Indication of the signal edge enable main ref value regardless of
the source selected in D119.
When the main reference value is switched during operation, the change must be accepted with an
enable signal. The enable can be level or edge-controlled. To obtain an acceptance, either a
positive edge must be determined for the signal enable main ref value (edge) or a HIGH level must
be determined for the signal enable main ref value (level).
0: inactive;
1: active;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 04 4F C0 00 hex
273Fh 0h
D320
Axis
read (2)
Level enable main ref value: Indication of the signal level enable main ref value regardless of
the source selected in D120.
When the main reference value is switched during operation, the change must be accepted with an
enable signal. The enable can be level or edge-controlled. To obtain an acceptance, either a
positive edge must be determined for the signal enable main ref value (edge) or a HIGH level must
be determined for the signal enable main ref value (level).
0: inactive;
1: active;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 04 50 00 00 hex
2740h 0h