Specifications

Comfort Reference Value – 5th Generation of STÖBER Inverters
STÖBER
ANTRIEBSTECHNIK
11. Used Parameters
KSW-181
D.. Reference Value
Par. Description Fieldbus-
address
D307
Axis
read (2)
Jog- source: Indication of the signal jog - regardless of the source selected in D107.
When jog mode is enabled, the signal jog ref value is output negated when the signal jog + is
active.
0: inactive;
1: active;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 04 4C C0 00 hex
2733h 0h
D308
Axis
read (2)
Positive blocking: Indicates the signal positive blocking regardless of the source selected in
D108.
When the signal positive blocking assumes the value 1:active, positive reference values are not
processed.
0: inactive;
1: active;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 04 4D 00 00 hex
2734h 0h
D309
Axis
read (2)
Negativ blocking: Indicates the signal negative blocking regardless of the source selected in
D109.
When the signal negative blocking assumes the value 1:active, negative reference values are not
processed.
0: inactive;
1: active;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 04 4D 40 00 hex
2735h 0h
D310
Axis
read (2)
Torque switch: The signal torque switch can be used to switch between the absolute torque
limits torque limit and torque limit 2. When the level is low, torque limit is active. When the level is
high, torque limit 2 is used.
D310 shows the signal regardless of the source selected in D110.
0: inactive;
1: active;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 04 4D 80 00 hex
2736h 0h
D311
Axis
read (2)
Master / slave switch: Indication of the signal master / slave switch regardless of the source
selected in D111.
When the signal master/slave switch assumes the value 1:active, the master reference value is
processed (selector D140).
0: inactive;
1: active;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 04 4D C0 00 hex
2737h 0h
D312
Axis
read (2)
Speed / torque switch: The signal speed/torque switch can be used to switch between speed
and torque control. When the level is low, speed control is active. When the level is high, torque
control is used.
D312 shows the signal regardless of the source selected in D112.
0: inactive;
1: active;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 04 4E 00 00 hex
2738h 0h
D313
Axis
read (2)
Additional enable 2: Indication of the signal additional enable 2 regardless of the source
selected in D113.
The signal additional enable 2 is logically linked with the reference value enables. If these are
activated (see D55), additional enable 2, a reference value enable and the device enables must
assume the value 1:active before the drive can be enabled.
0: inactive;
1: active;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 04 4E 40 00 hex
2739h 0h