Specifications

Comfort Reference Value – 5th Generation of STÖBER Inverters
STÖBER
ANTRIEBSTECHNIK
11. Used Parameters
KSW-180
D.. Reference Value
Par. Description Fieldbus-
address
D249
Axis
read (3)
Measure.unit: Read only. Internally used text. Derived from the text in D89. "/s" is added to the
text in D89. Is used as units string for user speeds.
Default setting: Upm/s
Fieldbus: Type: Str8; USS-Adr: 04 3E 40 00 hex
26F9h 0h
D300
Axis
read (2)
Reverse: Indicator parameter for the current signal state on the input of the speed block (reverse).
D300 shows the state regardless of the source selected in D100. In the "comfort reference value"
application, the signal can be read in D201 Bit 0 in fieldbus mode.
0: inactive;
1: active;
Fieldbus: 1LSB=1; PDO ; Type: B; USS-Adr: 04 4B 00 00 hex
272Ch 0h
D301
Axis
read (2)
External fault: Indicator parameter for the current signal state on the input of the speed block
(extFault). D301 shows the status regardless of the source selected in D101.
0: inactive;
1: active;
Fieldbus: 1LSB=1; PDO ; Type: B; USS-Adr: 04 4B 40 00 hex
272Dh 0h
D302
Axis
read (2)
Stop: Indicates the signal stop regardless of the source selected in D102.
When the stop signal is active, the reference value 0 is specified for the drive. The motor stops.
0: inactive;
1: active;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 04 4B 80 00 hex
272Eh 0h
D303
Axis
read (2)
Limit switch+: Indicates the signal limit switch+ regardless of the source selected in D103.
When the signal limit switch + is active, an event is triggered. The standard reaction is that the
device assumes the "fault" state. The direction after the limit switch is passed over is blocked. After
the fault is acknowledged, the drive can continue in the direction opposite from the switch.
0: inactive;
1: active;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 04 4B C0 00 hex
272Fh 0h
D304
Axis
read (2)
Limit switch-: Indicates the signal limit switch- regardless of the source selected in D104.
When the signal limit switch- is active, an event is triggered. The standard reaction is that the
device assumes the "fault" state. The direction after the limit switch is passed over is blocked. After
the fault is acknowledged, the drive can continue in the direction opposite from the switch.
0: inactive;
1: active;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 04 4C 00 00 hex
2730h 0h
D305
Axis
read (2)
Jog enable: Indicates the signal jog enable regardless of the source selected in D105.
When the drive comes to a standstill with an active stop signal (motor speed in window ±C40), jog
mode can be enabled with jog enable. The parameter D105 specifies the source for the signal. The
selections 0:low and 1:high correspond to fixed signal levels. When 2:parameter is selected, the
control word D210 Bit5 is used as the source. The control word can be written via fieldbus.
0: inactive;
1: active;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 04 4C 40 00 hex
2731h 0h
D306
Axis
read (2)
Jog+ source: Indication of the signal jog + regardless of the source selected in D106.
When jog mode is enabled, the signal jog ref value is output unchanged when the signal jog + is
active.
0: inactive;
1: active;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 04 4C 80 00 hex
2732h 0h