11. Used Parameters
KSW-179
D.. Reference Value
Par. Description Fieldbus-
address
D232
Global
r=2, w=2
Reference value external: Specification for the signal ref value external via fieldbus if the
signal source is D132=4:parameter.
Value range in %: -200.0 ... 0,0 ... 200.0
Fieldbus: 1LSB=0,1%; PDO ; Type: I16; (raw value:32767·LSB=200,0%); USS-Adr: 04 3A 00 00 hex
26E8h 0h
D233
Global
r=2, w=2
Correktion ref value 1: Specification for the signal correktion ref value 1 via fieldbus if the
signal source is D133=4:parameter.
Value range in %: -200.0 ... 0,0 ... 200.0
Fieldbus: 1LSB=0,1%; PDO ; Type: I16; (raw value:32767·LSB=200,0%); USS-Adr: 04 3A 40 00 hex
26E9h 0h
D234
Global
r=2, w=2
Correktion ref value 2: Specification for the signal correktion ref value 2 via fieldbus if the
signal source is D134=4:parameter.
Value range in %: -200.0 ... 0,0 ... 200.0
Fieldbus: 1LSB=0,1%; PDO ; Type: I16; (raw value:32767·LSB=200,0%); USS-Adr: 04 3A 80 00 hex
26EAh 0h
D235
Global
r=2, w=2
Jog ref value: Specification for the signal jog ref value via fieldbus if the signal source is
D135=4:parameter.
Value range in %: -200.0 ... 10,0 ... 200.0
Fieldbus: 1LSB=0,1%; PDO ; Type: I16; (raw value:32767·LSB=200,0%); USS-Adr: 04 3A C0 00 hex
26EBh 0h
D236
Axis
r=2, w=2
Max speed+ torque control: Specification for the signal max speed+ torque control via
fieldbus if the signal source is D136=4:parameter.
NOTE
This parameter is shown in rpm.
Value range in rpm: -8191 ... 3000 ... 8191
Fieldbus: 1LSB=1rpm; Type: I16; (raw value:32767 = 8191 rpm); USS-Adr: 04 3B 00 00 hex
26ECh 0h
D237
Axis
r=2, w=2
Max speed- torque control: Specification for the signal max speed- torque control via fieldbus
if the signal source is D137=4:parameter.
NOTE
This parameter is shown in rpm.
Value range in rpm: -8191 ... -3000 ... 8191
Fieldbus: 1LSB=1rpm; Type: I16; (raw value:32767 = 8191 rpm); USS-Adr: 04 3B 40 00 hex
26EDh 0h
D238
Axis
r=2, w=2
Max speed+ speed control: Specification for the signal max speed+ speed control via fieldbus
if the signal source is D138=4:parameter.
NOTE
This parameter is shown in user units. The user units are specified in D87 and D88.
Value range in D89: -8192 ... 3000 ... 8192
Fieldbus: 1LSB=siehe D86; PDO ; Type: I16; raw value:1LSB=Fnct.no.17; USS-Adr: 04 3B 80 00 hex
26EEh 0h
D239
Axis
r=2, w=2
Max speed- speed control: Specification for the signal max speed- speed control via fieldbus
if the signal source is D139=4:parameter.
NOTE
This parameter is shown in user units. The user units are specified in D87 and D88.
Value range in D89: -8192 ... -3000 ... 8192
Fieldbus: 1LSB=siehe D86; PDO ; Type: I16; raw value:1LSB=Fnct.no.17; USS-Adr: 04 3B C0 00 hex
26EFh 0h
D240
Global
r=2, w=2
Master reference: Specification for the signal master reference via fieldbus if the signal source
is D140=4:parameter.
Value range in %: -200.0 ... 0,0 ... 200.0
Fieldbus: 1LSB=0,1%; PDO ; Type: I16; (raw value:32767·LSB=200,0%); USS-Adr: 04 3C 00 00 hex
26F0h 0h