Specifications

Comfort Reference Value – 5th Generation of STÖBER Inverters
STÖBER
ANTRIEBSTECHNIK
11. Used Parameters
KSW-173
D.. Reference Value
Par. Description Fieldbus-
address
D187
Axis
read (1)
Motorised pot step reached: Indication of the signal depends on D43.
When the value 0 is entered in D43, the motor pot reference value changes continuously. The
signal motorized pot out constant has a high level when the signals motorized pot UP and
motorized pot DOWN are simultaneously inactive or active.
When D43 contains a value other than 0, the changes in reference value take place in steps. The
signal is 1:active when a step has been completed and 0:inactive when a new step has been
started.
The signal can be read in D200 Bit 13 in fieldbus mode.
0: inactive;
1: active;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 04 2E C0 00 hex
26BBh 0h
D188
Axis
read (1)
Motorised pot lim reached: When the level is high, the motorized pot reference value has
reached the value in D45 or D46.
The signal can be read in D200 Bit 14 in fieldbus mode.
0: inactive;
1: active;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 04 2F 00 00 hex
26BCh 0h
D189
Axis
read (1)
Zero ramp reached: When the level is high, the ramp generator has reached the value 0.
The signal can be read in D200 Bit 15 in fieldbus mode.
0: inactive;
1: active;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 04 2F 40 00 hex
26BDh 0h
D190
Axis
read (1)
Range control 1 red below: D190 is 1:active when the value indicated in D69 is below the
limit entered in D64 (D69 < D64). The application event 0 is triggered at the same time (parameters
U100 to U102).
The signal can be queried in D202 Bit 0 via fieldbus.
0: inactive;
1: active;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 04 2F 80 00 hex
26BEh 0h
D191
Axis
read (1)
Range control 1 yellow below: D191 is 1:active when the value indicated in D69 is between
the values D64 and D65 (D64 < D69 < D65).
The signal can be queried in D202 Bit 1 via fieldbus.
0: inactive;
1: active;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 04 2F C0 00 hex
26BFh 0h
D192
Axis
read (1)
Range control 1 green: D192 is 1:active when the value indicated in D69 is between the
values D65 and D66 (D65 < D69 < D66).
The signal can be queried in D202 Bit 2 via fieldbus.
0: inactive;
1: active;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 04 30 00 00 hex
26C0h 0h
D193
Axis
read (1)
Range control 1 yellow above: D193 is 1:active when the value indicated in D69 is between
the values D66 and D67 (D66 < D69 < D67).
The signal can be queried in D202 Bit 3 via fieldbus.
0: inactive;
1: active;
Fieldbus: 1LSB=1; Type: B; USS-Adr: 04 30 40 00 hex
26C1h 0h