Specifications
Table Of Contents
- Cover Sheet
- Table of Contents
- Notes on Safety
- Introduction
- Selecting the Type of Reference Value
- Representing the Reference Values in User Units
- Combining the Reference Values
- Available Reference Values
- Additional Functions
- Parameterizing the Speed and Torque Limits
- Additional Functions
- Fieldbus
- Used Parameters
- Global Presence
- Publication
- STÖBER Homepage
- STÖBER Product Range

Comfort Reference Value – 5th Generation of STÖBER Inverters
STÖBER
ANTRIEBSTECHNIK
11. Used Parameters
KSW-171
D.. Reference Value
Par. Description Fieldbus-
address
D137
Axis, OFF
r=1, w=1
Max V- torque control source: Selection of the source for the signal max. V- torque control. It
supplies the value for the negative speed limit during torque control.
The signal can be permanently preset and can be supplied by the analog inputs or the fieldbus.
When D137=4:parameter, the parameter D237 is used as the signal source. It can be written in
fieldbus mode.
The signal is indicated in D337 regardless of the selected source.
NOTE
This parameter is shown in user units. The user units are specified in D87 and D88.
0: 0 (zero);
1: AE1;
2: AE2;
3: AE3;
4: parameter;
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 04 22 40 00 hex
2689h 0h
D138
Axis, OFF
r=1, w=1
Max V+ speed control source: Selection of the source for the signal max. V+ speed control. It
supplies the value for the positive speed limit during speed control.
The signal can be permanently preset and can be supplied by the analog inputs or the fieldbus.
When D138=4:parameter, the parameter D238 is used as the signal source. It can be written in
fieldbus mode.
The signal is indicated in D338 regardless of the selected source.
NOTE
This parameter is shown in user units. The user units are specified in D87 and D88.
0: 0 (zero);
1: AE1;
2: AE2;
3: AE3;
4: parameter;
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 04 22 80 00 hex
268Ah 0h
D139
Axis, OFF
r=1, w=1
Max V- speed control source: Selection of the source for the signal max. V- speed control. It
supplies the value for the negative speed limit during speed control.
The signal can be permanently preset and can be supplied by the analog inputs or the fieldbus.
When D139=4:parameter, the parameter D239 is used as the signal source. It can be written in
fieldbus mode.
The signal is indicated in D339 regardless of the selected source.
NOTE
This parameter is shown in user units. The user units are specified in D87 and D88.
0: 0 (zero);
1: AE1;
2: AE2;
3: AE3;
4: parameter;
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 04 22 C0 00 hex
268Bh 0h
D140
Axis, OFF
r=1, w=1
Master reference source: Selection of the source for the signal master reference. This signal
can be used to implement a master-slave relationship via an analog coupling.
The signal can be permanently preset and can be supplied by the analog inputs or the fieldbus.
When D140=4:parameter, the parameter D240 is used as the signal source. It can be written in
fieldbus mode.
The reference value is specified for each source as a percentage. This reference value is indicated
in D340 as related to D56.
0: 0 (zero);
1: AE1;
2: AE2;
3: AE3;
4: parameter;
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 04 23 00 00 hex
268Ch 0h