11. Used Parameters
KSW-170
D.. Reference Value
Par. Description Fieldbus-
address
D133
Axis, OFF
r=1, w=1
Correktion ref value 1 source: Selection of the source for the signal correktion ref value 1.
The signal can be permanently preset and can be supplied by the analog inputs or the fieldbus.
When D133=4:parameter, the parameter D233 is used as the signal source. It can be written in
fieldbus mode.
The signal is indicated in D333 regardless of the selected source.
Scaling is done in the parameters D51.1, D52.1, D53.1 and D54.1.
0: 0 (zero);
1: AE1;
2: AE2;
3: AE3;
4: parameter;
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 04 21 40 00 hex
2685h 0h
D134
Axis, OFF
r=1, w=1
Correktion ref value 2 source: Selection of the source for the signal correktion ref value 2.
The signal can be permanently preset and can be supplied by the analog inputs or the fieldbus.
When D134=4:parameter, the parameter D234 is used as the signal source. It can be written in
fieldbus mode.
The signal is indicated in D334 regardless of the selected source.
Scaling is done in the parameters D51.2, D52.2, D53.2 and D54.2.
0: 0 (zero);
1: AE1;
2: AE2;
3: AE3;
4: parameter;
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 04 21 80 00 hex
2686h 0h
D135
Axis, OFF
r=1, w=1
Jog ref value source: Selection of the source for the signal jog ref value. The signal can be
permanently preset and can be supplied by the analog inputs or the fieldbus. When
D135=4:parameter, the parameter D235 is used as the signal source. It can be written in fieldbus
mode.
The signal is indicated in D335 regardless of the selected source.
Scaling is done in the parameters D51.3, D52.3, D53.3 and D54.3.
0: 0 (zero);
1: AE1;
2: AE2;
3: AE3;
4: parameter;
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 04 21 C0 00 hex
2687h 0h
D136
Axis, OFF
r=1, w=1
Max V+ torque control source: Selection of the source for the signal max. V+ torque control.
It supplies the value for the positive speed limit during torque control.
The signal can be permanently preset and can be supplied by the analog inputs or the fieldbus.
When D136=4:parameter, the parameter D236 is used as the signal source. It can be written in
fieldbus mode.
The signal is indicated in D336 regardless of the selected source.
NOTE
This parameter is shown in user units. The user units are specified in D87 and D88.
0: 0 (zero);
1: AE1;
2: AE2;
3: AE3;
4: parameter;
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 04 22 00 00 hex
2688h 0h