11. Used Parameters
KSW-167
D.. Reference Value
Par. Description Fieldbus-
address
D125.0
Axis, OFF
r=1, w=1
Fix reference source: A fix reference value is selected binary coded with the signals fix
reference 0 to 2.
The parameters D125.0 to D125.2 specify the sources for the signals fix reference 0 to 2. The
selections 0:low and 1:high correspond to fixed signal levels. The control word D212 Bit3 to Bit5 is
used as the source for the selection 2:parameter. The control word can be written via fieldbus.
The number of the selected fix reference value is indicated in D325.
NOTE
When preset reference values and fixed values are addressed via fieldbus, only eight preset
reference values are available. In this case, D212 Bit3 is evaluated as fixed value 0. When only
preset reference values are addressed in fieldbus mode, 16 preset reference values are available.
Fixed values can only be selected as adding and multiplying reference values (D31 and D33).
Value range: 0 ... 0: Low ... 28
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 04 1F 40 00 hex
267Dh
Array
0h
D125.1
Axis, OFF
r=1, w=1
fix reference source
Value range: 0 ... 0: Low ... 28
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 04 1F 40 01 hex
267Dh
Array
1h
D125.2
Axis, OFF
r=1, w=1
fix reference source
Value range: 0 ... 0: Low ... 28
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 04 1F 40 02 hex
267Dh
Array
2h
D126.0
Axis, OFF
r=1, w=1
Preset ref accelerating source: When the parameter D13 is set to 2:binary signals, an
acceleration ramp is selected with the signals preset ref acc selected 0 to 3.
The parameters D126.0 to D126.3 specify the sources for the signals preset ref acc selected 0 to 3.
The selections 0:low and 1:high correspond to fixed signal levels. The control word D212 Bit6 to
Bit9 is used as the source when 2:parameter is selected. The control word can be written via
fieldbus.
The number of the preset ref accelerating ramp is indicated in D326.
Value range: 0 ... 0: Low ... 28
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 04 1F 80 00 hex
267Eh
Array
0h
D126.1
Axis, OFF
r=1, w=1
preset ref accelerating source
Value range: 0 ... 0: Low ... 28
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 04 1F 80 01 hex
267Eh
Array
1h
D126.2
Axis, OFF
r=1, w=1
preset ref accelerating source
Value range: 0 ... 0: Low ... 28
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 04 1F 80 02 hex
267Eh
Array
2h
D126.3
Axis, OFF
r=1, w=1
preset ref accelerating source
Value range: 0 ... 0: Low ... 28
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 04 1F 80 03 hex
267Eh
Array
3h
D127.0
Axis, OFF
r=1, w=1
Preset ref decelerating source: When the parameter D13 is set to 2:binary signals, a
decelerating ramp is selected with preset ref dec selected 0 to 3.
The parameters D127.0 to D127.3 specify the sources for the signals preset ref dec selected 0 to 3.
The selections 0:low and 1:high correspond to fixed signal levels. The control word D212 Bit10 to
Bit13 is used as the source when 2:parameter is selected. The control word can be written via
fieldbus.
The number of the preset ref decelerating ramp is indicated in D327.
Value range: 0 ... 0: Low ... 28
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 04 1F C0 00 hex
267Fh
Array
0h