11. Used Parameters
KSW-166
D.. Reference Value
Par. Description Fieldbus-
address
8: BE3-inverted;
9: BE4;
10: BE4-inverted;
11: BE5;
12: BE5-inverted;
13: BE6;
14: BE6-inverted;
15: BE7;
16: BE7-inverted;
17: BE8;
18: BE8-inverted;
19: BE9;
20: BE9-inverted;
21: BE10;
22: BE10-inverted;
23: BE11;
24: BE11-inverted;
25: BE12;
26: BE12-inverted;
27: BE13;
28: BE13-inverted;
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 04 1E 00 00 hex
D124.0
Axis, OFF
r=1, w=1
Preset reference source: A preset reference value is selected binary coded with the signals
preset reference 0 to 3.
The parameters D124.0 to D124.3 specify the sources for the signals preset reference 0 to 3. The
selections 0:low and 1:high correspond to fixed signal levels. The control word D212 Bit0 to Bit3 is
used as the source for the selection 2:parameter. The control word can be written via fieldbus.
The number of the selected preset reference value is indicated in D324.
NOTE
When preset reference values and fixed values are addressed via fieldbus, only eight preset
reference values are available. In this case, D212 Bit3 is evaluated as fixed value 0. When only
preset reference values are addressed in fieldbus mode, 16 preset reference values are available.
Value range: 0 ... 0: Low ... 28
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 04 1F 00 00 hex
267Ch
Array
0h
D124.1
Axis, OFF
r=1, w=1
preset reference source
Value range: 0 ... 0: Low ... 28
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 04 1F 00 01 hex
267Ch
Array
1h
D124.2
Axis, OFF
r=1, w=1
preset reference source
Value range: 0 ... 0: Low ... 28
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 04 1F 00 02 hex
267Ch
Array
2h
D124.3
Axis, OFF
r=1, w=1
preset reference source
Value range: 0 ... 0: Low ... 28
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 04 1F 00 03 hex
267Ch
Array
3h