Comfort Reference Value – 5th Generation of STÖBER Inverters
STÖBER
ANTRIEBSTECHNIK
11. Used Parameters
KSW-164
D.. Reference Value
Par. Description Fieldbus-
address
13: BE6;
14: BE6-inverted;
15: BE7;
16: BE7-inverted;
17: BE8;
18: BE8-inverted;
19: BE9;
20: BE9-inverted;
21: BE10;
22: BE10-inverted;
23: BE11;
24: BE11-inverted;
25: BE12;
26: BE12-inverted;
27: BE13;
28: BE13-inverted;
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 04 1D 40 00 hex
D118.0
Axis, OFF
r=1, w=1
Main ref value source: The binary coded main-reference-value-select signals can be used
during operation to choose between various main reference value sources (e.g., reference value,
correction reference value or motor potentiometer). The selection with the main-reference-value-
selectors takes precedence over the setting in D30. The parameters D118.0 to D118.2 specify the
sources for the signals main reference value 0 to 2. The selections 0:low and 1:high correspond to
fixed signal levels. When the selection is 2:parameter, the control word D211 Bit 7 to Bit 9 is used
as the source. The control word can be written via fieldbus.
The signal is indicated in D318 regardless of the selected source.
Main reference value 0 to 2 Reference value
Binary Decimal
000 0 Ref value external
001 1 Preset ref value
010 2 Correct ref1
011 3 Motorized pot
100 4 Correct ref2
101 5 PID
110 6 n-actual
NOTE
With binary coding, the signal main reference value 0 supplies the LSB and main reference value 2
supplies the MSB.
Value range: 0 ... 0: Low ... 28
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 04 1D 80 00 hex
2676h
Array
0h
D118.1
Axis, OFF
r=1, w=1
main ref value source
Value range: 0 ... 0: Low ... 28
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 04 1D 80 01 hex
2676h
Array
1h
D118.2
Axis, OFF
r=1, w=1
main ref value source
Value range: 0 ... 0: Low ... 28
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 04 1D 80 02 hex
2676h
Array
2h