11. Used Parameters
KSW-163
D.. Reference Value
Par. Description Fieldbus-
address
D116
Axis, OFF
r=1, w=1
Motorised pot preset source: A HIGH level of the signal motorized pot preset resets the
motorized pot reference value to the value entered in D44 (edge or level-triggered depending on
D40 Bit6).
The parameter D116 specifies the source for the signal motorized pot preset. The selections 0:low
and 1:high correspond to fixed signal levels. When the selection is 2:parameter, the control word
D211 Bit2 is used as the source. The control word can be written via fieldbus.
Regardless of the selected source, the signal is indicated in D316. If the signal is to be processed
with time delay, a "switchon" delay can be parameterized in D416.0 and a "switchoff" delay in
D416.1.
0: Low;
1: High;
2: parameter;
3: BE1;
4: BE1-inverted;
5: BE2;
6: BE2-inverted;
7: BE3;
8: BE3-inverted;
9: BE4;
10: BE4-inverted;
11: BE5;
12: BE5-inverted;
13: BE6;
14: BE6-inverted;
15: BE7;
16: BE7-inverted;
17: BE8;
18: BE8-inverted;
19: BE9;
20: BE9-inverted;
21: BE10;
22: BE10-inverted;
23: BE11;
24: BE11-inverted;
25: BE12;
26: BE12-inverted;
27: BE13;
28: BE13-inverted;
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 04 1D 00 00 hex
2674h 0h
D117
Axis, OFF
r=1, w=1
Motorised pot ramp source: When D40 Bit7 is active, the signal motorized pot ramp can be
used to switch between the ramps D41 and D42. D41 is used for a low level. The ramp D42 is used
for a high level.
The parameter D117 specifies the source for the signal motorized pot ramp. The selections 0:low
and 1:high correspond to fixed signal levels. When the selection is 2:parameter, the control word
D211 Bit3 is used as the source. The control word can be written via fieldbus.
Regardless of the selected source, the signal is indicated in D317. When the signal is to be
processed with time delay, a "switch on" delay can be parameterized in D417.0 and a "switch off"
delay in D417.1.
0: Low;
1: High;
2: parameter;
3: BE1;
4: BE1-inverted;
5: BE2;
6: BE2-inverted;
7: BE3;
8: BE3-inverted;
9: BE4;
10: BE4-inverted;
11: BE5;
12: BE5-inverted;
2675h 0h