11. Used Parameters
KSW-162
D.. Reference Value
Par. Description Fieldbus-
address
15: BE7;
16: BE7-inverted;
17: BE8;
18: BE8-inverted;
19: BE9;
20: BE9-inverted;
21: BE10;
22: BE10-inverted;
23: BE11;
24: BE11-inverted;
25: BE12;
26: BE12-inverted;
27: BE13;
28: BE13-inverted;
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 04 1C 80 00 hex
D115
Axis, OFF
r=1, w=1
Motorised pot down source: A HIGH level of the signal motorized pot DOWN decreases the
motorized pot reference value as step or continuously, depending on D43.
The parameter D115 specifies the source for the signal motorized pot DOWN. The selections 0:low
and 1:high correspond to fixed signal levels. When the selection is 2:parameter, the control word
D211 Bit1 is used as the source. The control word can be written via fieldbus.
Regardless of the selected source, the signal is indicated in D315.
0: Low;
1: High;
2: parameter;
3: BE1;
4: BE1-inverted;
5: BE2;
6: BE2-inverted;
7: BE3;
8: BE3-inverted;
9: BE4;
10: BE4-inverted;
11: BE5;
12: BE5-inverted;
13: BE6;
14: BE6-inverted;
15: BE7;
16: BE7-inverted;
17: BE8;
18: BE8-inverted;
19: BE9;
20: BE9-inverted;
21: BE10;
22: BE10-inverted;
23: BE11;
24: BE11-inverted;
25: BE12;
26: BE12-inverted;
27: BE13;
28: BE13-inverted;
Fieldbus: 1LSB=1; Type: U8; USS-Adr: 04 1C C0 00 hex
2673h 0h